Door control TS · PDF file Maintenance cycle counter Maintenance cycle counter Maintenance...

Click here to load reader

  • date post

    22-Mar-2020
  • Category

    Documents

  • view

    5
  • download

    2

Embed Size (px)

Transcript of Door control TS · PDF file Maintenance cycle counter Maintenance cycle counter Maintenance...

  • en

    Installation instructions

    Door control TS 959

    51171547_d_03_2014

    0 0 0 0 0 0 0 0 0 0 0 5 1 1 7 1 5 4 7 XXXXX

  • 2

    GfA - Gesellschaft für Antriebstechnik GmbH Wiesenstraße 81 D-40549 Düsseldorf www.gfa-elektromaten.de

    info@gfa-elektromaten.de

  • 3

    Table of contents 1  General safety information ............................................................................................ 5  2  Technical data .............................................................................................................. 6  3  Mechanical installation .................................................................................................. 7  4  Electrical installation ..................................................................................................... 8 

    Cable connection overview ............................................................................................... 9  Limit switch assignment for screwable version until year of manufacture of 1997 .......... 10  Assignment of individual limit switches ........................................................................... 10  Carrying out the electrical installation .............................................................................. 11  Mains connection ............................................................................................................ 12  Mains connection to control ............................................................................................ 12  Completing the electrical installation ............................................................................... 12  Overview of control panel ................................................................................................ 13 

    5  Initial operation of the control ...................................................................................... 14  DES: Rapid adjustment of final limit positions ................................................................. 14  NES: Rapid adjustment final limit positions ..................................................................... 15 

    6  Advanced electrical installation.................................................................................... 16  External supply X1 .......................................................................................................... 16  Emergency stop X3 ......................................................................................................... 16  Relay contact X20 ........................................................................................................... 16  Control device X5 ............................................................................................................ 16  Spiral cable connection ................................................................................................... 16 

    7  Programming the control ............................................................................................. 17  8  Table of menus ........................................................................................................... 18 

    Operating mode .............................................................................................................. 18  Door positions ................................................................................................................. 18  Door functions ................................................................................................................. 19  Safety functions .............................................................................................................. 19  Maintenance cycle counter ............................................................................................. 20  Reading out memory ....................................................................................................... 21  Delete all settings ............................................................................................................ 21 

    9  Safety devices ............................................................................................................ 22  X2: Input, door safety switch ........................................................................................... 22  X3: Input, emergency stop .............................................................................................. 22 

  • 4

    10  Functional description ................................................................................................. 23  X1: Mains supply line for control and external supply ..................................................... 23  X5: Input, control device .................................................................................................. 24  Advanced hold-to-run function ........................................................................................ 24  X20: Floating relay contact .............................................................................................. 25  Force monitoring (DES only) ........................................................................................... 25  Travel time monitoring (NES only)................................................................................... 26  Maintenance cycle counter .............................................................................................. 27  Short-circuit/Overload display ......................................................................................... 27  Standby function ............................................................................................................. 27 

    11  Status display ............................................................................................................. 28  12  Explanation of symbols ............................................................................................... 32  13  Declaration of Incorporation/Declaration of Conformity ................................................ 34 

    Symbols

    Warning - Risk of injury or danger to life!

    Warning - Danger to life through electrical current!

    Note - Important information!

    ▶ Request - Required action!

    Illustrations show example products. Deviations from the delivered product are possible.

  • 5

    1 General safety information

    Specified normal use The door control is intended for a power-operated door with a drive unit. The safe operation is only guaranteed with normal specified use. The drive unit is to be protected from rain, moisture and aggressive ambient conditions. No liability for damage caused by other applications or non-observance of the information in the manual. Modifications are only permitted with the agreement of the manufacturer. Otherwise the Manufacturer’s Declaration shall be rendered null and void. Safety information Installation and initial operation tasks are to be performed by trained, skilled fitters only. Only trained electrical craftsmen are permitted to work on electrical equipment. They must assess the tasks assigned to them, recognise potential danger zones and be able to take appropriate safety measures. Installation work is only to be carried out with the supply off. Observe the applicable regulations and standards. Coverings and safety devices Do not operate unless corresponding coverings and safety devices are fitted/installed. Ensure that gaskets are correctly positioned and cable glands are correctly tightened. Spare parts Use only original spare parts.

  • 6

    2 Technical data

    Series TS 959

    Dimensions W x H x D 155 x 386 x 90 mm

    Assembly vertical

    Vibration Assembly free of vibration

    Operating frequency 50/60 Hz

    Supply voltage (+/- 10%) 1 N~220 V, PE 3 N~220-400 V, PE 3~220-400 V, PE

    Output power for drive unit, maximum 3 kW

    Backup fuse per phase, on-site 10-16 A

    External mains supply: X1/L, X1/N (backup fuse via F1 micro-fuse)

    1 N~230 V

    1.6 A time-lag

    Control inputs 24 V DC

    type 10 mA

    Type relay contact Max. current of 1A at 230VAC, and 0.4A at 24VDC (The use of LED lamps is recommended.)

    floating changeover contacts

    Loading of relay contacts, ohmic/inductive

    230 V AC

    1 A

    Control power consumption 10 VA

    Temperature range Operation: -5..+40 Storage: +0..+50 °C

    Humidity up to 93 % non-condensing

    Class of protection of housing IP54

    Compatible GfA limit switch NES; DES

  • 7

    3 Mechanical installation

    Control installation!  Only use indoors  Mounting only on a level ground free of vibration  Only vertical mounting position permissible  Door must be visible from the assembly site

    Prerequisites The permissible loads of walls, mountings, connecting and transmission elements must not be exceeded.

    Mounting

    The control is mounted via 4 elongated holes

  • 8

    4 Electrical installation

    Warning - Risk of electrocution!  Disconnect the cables and check that they are de-energised  Observe the applicable regulations and standards  Make a proper electrical connection  Use suitable tools

    On-site backup fuse and disconnector unit!  Connection to the indoor installation via all-pole disconnector unit ≥ 10 A as per