SunRise "Démonstrateur de la ville intelligente et Durable" : Etat d'avancement et Perspectives

download SunRise "Démonstrateur de la ville intelligente et Durable" : Etat d'avancement et Perspectives

of 42

  • date post

    17-Jul-2015
  • Category

    Environment

  • view

    204
  • download

    0

Embed Size (px)

Transcript of SunRise "Démonstrateur de la ville intelligente et Durable" : Etat d'avancement et Perspectives

  • SunRise : dmonstrateur de la Ville intelligente et durable

    Etat davancement Pistes de dveloppement

    Rencontres Sciences et Technologies Parc Scien9fique de la Haute Borne 24 Mars 2015

    Isam Shahrour, Universit Lille1 Jean Marc Charlemagne, Eaux du Nord

  • Pe8te ville (110 Hectares) 25 000 usagers 140 b9ments

    varit usage qualit de construc9ons

    Projet SunRise Cit Scien8fique

  • 70 km de rseaux

    Eau potable Assainissement Chauffage urbain, Gaz lectricit (HT, BT) Eclairage public Voiries

  • Plateforme de pilotage Systme dinforma8on

    Donnes de patrimoine (SIG) Donnes dtat et de

    fonc8onnement (capteurs, ..) Informa8ons libres

    Ou8ls danalyse

    Communica8on Serveur web

    Equipes Techniques Equipes de ges8ons Usagers Equipes Acadmiques Partenaires

    Architecture du systme de SunRise

    Communica8on : Rseaux filaires Rseaux sans fils

    B8ments (habitat, ac8vits,..) Rseaux (eau, nergie, voirie,..)

    Mesure et contrle des infrastructures

    Autres Donnes

    Environnement Transport Informa8ons Secours .

  • Eau potable

  • Projets en cours :

    1) Laboratoire commun Rseaux deau intelligents Partenaires : CEA-LIST, W-Smart, KWR

    2) Chaire Industrielle Partenaire : Eaux du Nord

    3) Projet INCOM (Fuites) Partenaires : Eaux du Nord, CEA-LIST, Eaux de Paris, W-Smart, Vitens

    4) Projet BioSmart (Bio Contamina9on) Partenaires : Eaux du Nord, CEA-LIST, Eaux de Paris, W-Smart, Vitens

  • TWUL Demo site London

    Smart Caceres Caceres

    VIP Leeuwarden

    Sunrise Lille

    Projet Europen SmartWater4Europe

  • SmartWater4Europe

  • Instrumenta8on

  • Consomma8on d'eau du b8ment P2 - Mai 2014

  • Sectorisa9on

  • Intellisonde

    Qualit

  • Pilote en laboratoire

  • Rseau dassainissement

  • Rseau secondaire (USTL)

    Rseau principal (LMCU)

    16 km 740 Regards

  • 17

    Regards

  • Pompe de relevage

  • Chauffage Urbain

  • SunRise Site pilote de la ville intelligente et durable

    Rseau d'eau Rseau de chauffage

    Composantes du rseau de chauffage

    Chaufferie Sta9ons dchanges

  • Les sta8ons dchange

    Sous sta9on M1

  • SunRise Site pilote de la ville intelligente et durable

    Rseau d'eau Rseau de chauffage

    Systme de rgula9on

  • B8ment M1

    Consomma8on Temprature extrieure

  • Courbe de chauffe (2012)

  • Rseau Electrique

  • Electrical Grid Network

    A2

    M6

    HT (20 kV)

    LT

    Supply

    FAULT

  • Substa8on M1

    HT Line leaving M1 and

    des9ned for next post on the loop

    High Tension Distribu8on Panel (TGHT)

    Transformer 1s Cell (protects

    transformer #1)

    Transformer 2s Cell (protects

    transformer #2)

    HT Line arriving into M1 from Previous HT

    Post

    H.T (20 kV) L.T. (380 V)

    Smart Meter loca9on recording & compiling consump9on (kWh) data, and

    then sending to the main server

    Low Voltage Master Distribu8on Panel (TGBT)

  • Current Levels

    Minimum On Sun 9/7/2014 110 A

    Average 213 A

    Maximum On Tue 10/21/2014 414 A

    Sta8s8cs Data Change over the last 92 day(s)

    Historical Data Change over one day 9/1/2014 Date Time Current [A] Mon 09/01/14 00:00:00 166 A Mon 09/01/14 00:00:52 161 A Mon 09/01/14 00:01:52 158 A Mon 09/01/14 00:02:52 164 A

    Mon 09/01/14 12:14:02 209 A

    Mon 09/01/14 12:15:02 216 A

    Mon 09/01/14 12:16:02 223 A

    Mon 09/01/14 12:17:02 211 A

    Mon 09/01/14 12:18:02 203 A

    CP_Electricit - Gnral - Poste Bachelard - Current L1

  • EDF Contract

    0

    1 000

    2 000

    3 000

    4 000

    5 000

    6 000

    Friday, March 01,

    2013

    Monday, April 01, 2013

    Wednesday, May 01, 2013

    Saturday, June 01, 2013

    Monday, July 01, 2013

    Thursday, August 01,

    2013

    Sunday, September 01, 2013

    Tuesday, October 01,

    2013

    Friday, November 01, 2013

    Sunday, December 01, 2013

    Wednesday, January 01,

    2014

    Saturday, February 01,

    2014

    Saturday, March 01,

    2014

    Tuesday, April 01, 2014

    Consum

    p8on

    ]kWh]

    Date

    Fixed Demand Charge V.S. Real Demand Charge

  • logement social

  • Cahier des charges LMH/LGCgE Suivre en temps rel

    Les paramtres de confort: Temprature Humidit Qualit de lair Luminosit Bruit

    Les consomma8ons: lectricit Chauffage Eau

    Dautres paramtres: Prsence Ouvertures Alarme incendie

  • Appartement pdagogique

    Qualit dair intrieur Luminosit / Prsence

    Consomma9on lectrique

    Temprature / Humidit

  • Consomma2on Electrique

    0

    500

    1000

    1500

    2000

    2500

    3000

    3500

    1065000

    1065500

    1066000

    1066500

    1067000

    1067500

    1068000

    1068500

    1069000

    1069500

    1070000

    0:04

    1:24

    2:44

    4:04

    5:24

    6:44

    8:04

    9:24

    10:44

    12:04

    13:24

    14:44

    16:04

    17:24

    18:44

    20:04

    21:24

    22:44

    0:04

    1:24

    2:44

    4:04

    5:24

    6:44

    8:04

    9:24

    10:44

    12:04

    13:24

    14:44

    16:04

    17:24

    18:44

    20:04

    21:24

    22:44

    0:04

    1:24

    2:44

    4:04

    5:24

    6:44

    8:04

    9:24

    10:44

    12:03

    13:23

    Index [Wh] Puissance Apparente [VA]

    12/02/2014 13/02/2014 14/02/2014

  • Logements occups

    Verhaeren 1935

    Charles Sixte 1975

  • Dmonstrateur Voirie : Impact de la tranche

  • Aot 2014

  • 32

    Humidit Temprature Dforma8on Pression Tassement Fissura8on Fibre op8que

    20 28 32 10 1 4 2

  • Les pistes de dveloppement

  • Pourquoi ? Quoi ? Comment ?

    Diagnos9c Concerta9on Stratgie Modle conomique Gouvernance

    Smart City ??

  • Capteurs

    - Energie - Miniaturisa8on - Mul8 paramtres - Bio, chimie,.. ?? - Intelligence intgre - Communica8on (porte,..) - Interac8on M&M - Design - Fiabilit , scurit - Localisa8on, densit - Cot

    Ac8onneurs

    Capteurs

    Capteurs

    Fiabilit Scurit Couverture

    Stockage Analyse (spa8ale,

    temporelle,..) Appren8ssage Interac8on usagers

    (graphique, RV, RA,) Scurit