Post on 06-Feb-2022
AA
D
E
F
C
B
321 54 6 7 8
C
D
B
E
F
1 2 3 4 5 6 7 8
PO BOX 145COLLAROY BEACH, NSW 2097
AUSTRALIA
office@evocoengineering.comevocoengineering.com
CLIENT:
APPROVEDDRAWNDESCRIPTIONDATEREV
IF THIS BAR DOESNOT MEASURE 20mmTHEN DRAWING IS
NOT TO SCALE
ALL DIMENSIONS INMILLIMITRES UNLESSOTHERWISE STATED
APPROVED:
CHECKED:
DESIGNED:
DRAWN:
PROJECT Nº:
SHEET:
DRAWING Nº:
ORIG. SIZE:
REV.:
SCALE: PROJECT:
TITLE:
DRAWING SET Nº50 10 20
222
3 W
ALL
HEIG
HT
6038 OD
ASL60 - SIDE ELEVATION
BOLT COVER PLATE7 OFF REQUIRED
CUSTOM ORB 16BMT 0.42 WIDTH 762
1530
15
30
6021 NOMINAL DIAMETER
CL
TRUSS1
ASL60 - PLAN VIEW
TRUSS1
TRUSS2
TANK WALL SHEETINGJOINTS,7 OFF
AB
DIMETRIC VIEW
STRAINER
MANWAY COVER
LADDER
AAAADH
E
SWIVELBRACKETCONNECTIONDETAIL
SECTION AA-AA
DETAIL A1 : 5
DETAIL A1:5
ISOMETRIC VIEWTRUSS SWIVEL BRACKET-ROOF RING CONNECTION DETAIL
ROOF SHEETS HIDDEN FOR CLARITY
GUSSET
LOOSE WASHER
SWIVEL BRACKET
END CAP
TOP RING
M8 GALVANIZED BOLTS
NOTES: DESIGNED WATER HEIGHT: 2.22mDESIGNED CAPACITY OF THE TANK: 61 811L
DESIGN DATAThe structural components have been designed in accordancewith the relevant Australian Standards for the following loads:Live load to AS/NZS1170.1 and AS1657· Roof live load = 1.1 kN, 0.25 kPa· Ladder live load = 1.5 kN
Wind load to AS/NZS1170.2· Region = A & B· Structure Importance Level = 2· Regional wind speed V(500)= 57 m/s· Terrain category = 2.5
Earthquake load to AS1170.4· Earthquake Design Category = NilAtmospheric Exposure to AS4312· Atmospheric Exposure Category = C2: Low, or T: Inland Tropical
THIS DESIGN AND DRAWING IS THE SOLE PROPERTY OF EVOCO ENGINEERING PTY LTD. ANY COPY, REPRODUCTION, MODIFICATION AND/OR TRANSMITTAL OF ANY INFORMATION CONTAINED WITHIN THIS DRAWING MAY ONLY OCCURE WITH THE WRITTEN PERMISSION OF THE COMPANY.
T PiskoP1 10/07/21 PRELIMINARY RELEASE P.R. ASL60-2223-WRAB-STD
1/2 A
A3
C:\Users\tomas\Dropbox (Tomas)\EVOCO Engineering Pty Ltd\Projects\Bushmans Group\Aqualine Steel Tanks V2\ASL60\
PRIN
T DA
TE: S
atur
day,
31 J
uly
2021
1:60 AQUALINE TANK ASL60WIND REGION A & B
GENERAL ARRANGEMENT AND DETAILSALES DRAWING
C R Rohde
P Rupasinghe
P Rupasinghe
ASL60
GPO 4218, NSW, SYDNEY, 2001
WWW.BUSHMANTANKS.COM.AU
BUSHMANS HEAD OFFICE
BUSHMANS GROUP PTY LTD
T.P.P.R.T.P.RELEASED FOR PRODUCTION31/07/21A
AA
D
E
F
C
B
321 54 6 7 8
C
D
B
E
F
1 2 3 4 5 6 7 8
PO BOX 145COLLAROY BEACH, NSW 2097
AUSTRALIA
office@evocoengineering.comevocoengineering.com
CLIENT:
APPROVEDDRAWNDESCRIPTIONDATEREV
IF THIS BAR DOESNOT MEASURE 20mmTHEN DRAWING IS
NOT TO SCALE
ALL DIMENSIONS INMILLIMITRES UNLESSOTHERWISE STATED
APPROVED:
CHECKED:
DESIGNED:
DRAWN:
PROJECT Nº:
SHEET:
DRAWING Nº:
ORIG. SIZE:
REV.:
SCALE: PROJECT:
TITLE:
DRAWING SET Nº50 10 20
5089 SHS
1272.5
2547.5
5095 O/A
SPLICE
ASL60 TRUSS 1 ELEVATION2 OFF HOT DIPPED GALVANIZED TRUSSES
CALCULATED MASS: 22.5 KG
CL
R19940CENTERLINE
5944 SHS 5950 O/A
1486
2975
C
SPLICE
ASL60 TRUSS 2 ELEVATION1 OFF HOT DIPPED GALVANIZED TRUSSES
CALCULATED MASS: 26.5 KG
CL
R20000CENTERLINE
226
.1
2547.5 2547.5
ASL60 TRUSS 1EXPLODED VIEW
286
2975 2975
ASL60 TRUSS 2EXPLODED VIEW
END PLATE 20
10
DETAIL C1 : 5
TRUSS END DETAIL
FLAT WASHER(LOOSE)
Ø18 FOR M16 8.8/S x90GAL BOLT
GUSSET
DETAIL B1 : 5
ISOMETRIC VIEWSPLICE PLATE CONNECTION DETAILROOF SHEETS HIDDEN FOR CLARITY
4 - M10 8.8/S x 35 GALVANIZED
THIS DESIGN AND DRAWING IS THE SOLE PROPERTY OF EVOCO ENGINEERING PTY LTD. ANY COPY, REPRODUCTION, MODIFICATION AND/OR TRANSMITTAL OF ANY INFORMATION CONTAINED WITHIN THIS DRAWING MAY ONLY OCCURE WITH THE WRITTEN PERMISSION OF THE COMPANY.
T PiskoP1 01/07/21 PRELIMINARY RELEASE P.R. ASL60-2223-WRAB-STD
2/2 A
A3
C:\Users\tomas\Dropbox (Tomas)\EVOCO Engineering Pty Ltd\Projects\Bushmans Group\Aqualine Steel Tanks V2\ASL60\
PRIN
T DA
TE: S
atur
day,
31 J
uly
2021
1:40 AQUALINE TANK ASL60WIND REGION A & B
TRUSS ARRANGEMENT AND DETAILSSALES DRAWING
C R Rohde
P Rupasinghe
P Rupasinghe
ASL60
GPO 4218, NSW, SYDNEY, 2001
WWW.BUSHMANTANKS.COM.AU
BUSHMANS HEAD OFFICE
BUSHMANS GROUP PTY LTD
T.P.P.R.T.P.RELEASED FOR PRODUCTION31/07/21A