SYSTÈME HYDROSTOR HS75 DE SOLENO, 12-01-2021 · 2021. 1. 14. · 250mm pour puits d'accÈs g f e...
Transcript of SYSTÈME HYDROSTOR HS75 DE SOLENO, 12-01-2021 · 2021. 1. 14. · 250mm pour puits d'accÈs g f e...
305mm
152mm MIN
152mm MIN
2.438m MAX
755mm
305mm MIN 152mm MIN
1.295m
457mm MIN 610mm MIN
PIERRE NETTE 19mm (3/4")40% VIDE
REMBLAI INITIAL COMPACTÉ À 90% P.M.
REMBLAI FINAL
D
C
INSTALLATION RECOMMANDÉE DU SYSTÈMEHYDROSTOR HS75
CHAUSSÉE INFRASTRUCTUREDE CHAUSSÉE
EXEMPLE D'UN AMÉNAGEMENT TYPIQUEHYDROSTOR HS75
I
J
IH
G F
HE
B
AH
I
H
K
L
E
C
C
EMBOUT HYDROSTOR HS75AVEC COUDE SOUDÉ SOLFLO MAX
250mm POUR PUITS D'ACCÈS
G
F
EE
755mm
2.212m
CHAMBRE HYDROSTOR HS75
B
295mm 2.156m
LONGUEURS ASSEMBLÉES
AB
305mm MIN
100mm
TUYAU À RACCORDER(PVC, PEHD, ETC.)
SELLETTE UNIVERSELLEDIAMÈTRE MAX 200mm
GÉOTEXTILE TISSÉ DESTABILISATION 300 WHTM
DÉTAIL DE RACCORDEMENT LATÉRAL
NE PAS INSTALLERLA SELLETTE UNIVERSELLESUR LES ONDULATIONS AUX
EXTRÉMITÉS.
LA SELLETTE UNIVERSELLEDOIT ÊTRE INSTALLÉE, CENTRÉE
SUR L'ONDULATION
CADRE ET COUVERCLEDE FONTE AJUSTABLE 250mm
FF
1.222m
747mm
EMBOUT HYDROSTOR HS75
A
4.570m C
VUE DESSUS
L’INSTALLATION DOIT ÊTRE FAITE SELON LES RECOMMANDATIONS DU MANUFACTURIER.1.LE SYSTÈME EST CONÇU POUR RÉSISTER STRUCTURALEMENT AUX SURCHARGES DE CIRCULATION CSA CL-625 ET AASHTO H-20.2.LES CHAMBRES HS75 DOIVENT ÊTRE MINIMALEMENT REMBLAYÉES DE 152mm DE PIERRE NETTE ET DE 305mm DE MATÉRIAU GRANULAIRE COMPACTÉ À 90% P.M.3.LE GÉOTEXTILE TISSÉ DE STABILISATION 300 WHTM EST PRÉVU SOUS TOUTES LES CHAMBRES RECEVANT UN APPORT D’EAU (SUR UNE LONGUEUR DE 4.57M) AINSI QUE SOUS LES CHAMBRES4.INCLUANT UN PUITS D’ACCÈS (LORSQUE LE PUITS EST INSTALLÉ SUR L’EMBOUT, LE GÉOTEXTILE TISSÉ SE RETROUVE SOUS CELUI-CI AINSI QUE SOUS LA CHAMBRE ADJACENTE)
ITEM DESCRIPTION
A EMBOUT HYDROSTOR HS75
B CHAMBRE HYDROSTOR HS75
C GÉOTEXTILE TISSÉ DE STABILISATION 300 WHTM
D GÉOTEXTILE DE SÉPARATION NON-TISSÉ SOLENO TX-90, AU-DESSUS, EN DESSOUS ET SUR LES CÔTÉS
E EMBOUT HYDROSTOR HS75 AVEC COUDE SOUDÉSOLFLO MAX 250mm POUR PUITS D'ACCÈS
F CADRE ET COUVERCLE DE FONTE AJUSTABLE 250mm
G PUITS D'ACCÈS PVC 250mm (FOURNI PAR D'AUTRES)
H LONG. STD 6m SOLFLO MAX 300mm
I COUDE SOLFLO MAX 300mm
J CROIX SOLFLO MAX 300mm
K TÉ SOLFLO MAX 300mm
L UNITÉ DE PRÉTRAITEMENT
2021-01-12
SYSTÈME HYDROSTOR HS75 DE SOLENO
LE DOCUMENT EST LA PROPRIÉTÉ DE SOLENO. IL NE PEUT ÊTRE REPRODUIT SANS NOTRE CONSENTEMENT.
305mm
152mm MIN
152mm MIN
2.438m MAX
755mm
305mm MIN 152mm MIN
1.295m
457mm MIN 610mm MIN
CRUSHED WASHED STONE 19mm (3/4")40% POROSITY
INITIAL BACKFILL 90% COMPACTED P.M.
FINAL BACKFILL
D
C
RECOMMENDED INSTALLATION OFHYDROSTOR HS75 SYSTEM
PAVEMENT PAVEMENT BASE
HYDROSTOR HS75CONFIGURATION EXAMPLE
I
J
IH
G F
HEE
B
AH
I
H
K
L
C
C
HYDROSTOR END CAP HS75 WITHWELDED ELBOW SOLFLO MAX
250mm FOR ACCESS WELL
G
F
EE
755mm
2.212m
HYDROSTOR CHAMBER HS75
B
295mm 2.156m
ASSEMBLED LENGTH
AB
305mm MIN
100mm
CONVEYANCE PIPEMATERIAL MAY VARY
(PVC, HDPE, ETC.)
UNIVERSAL SOL-TEE CONNECTIONMAX DIAMETER 200mm
STABILIZATION NETTINGHYDROSTOR
LATERAL UNIVERSAL SOL-TEE DETAIL
DO NOT INSTALLUNIVERSAL SOL-TEE AT
CHAMBER JOINTS
UNIVERSAL SOL-TEE TO BEINSTALLED, CENTERED
OVER CORRUGATION
AJUSTABLE FRAMEAND COVER 250mm
FF
1.222mm
747mm
HYDROSTOR END CAP HS 75
A
4.570m C
TOP VIEW
INSTALLATION MUST BE MADE IN ACCORDANCE WITH THE MANUFACTURER’S RECOMMENDATIONS.1.SYSTEM IS DESIGNED TO WITHSTAND TRAFFIC LOAD CSA CL-625 AND AASHTO H-20.2.HS75 CHAMBERS MUST BE MINIMALLY BACKFILLED WITH 152mm OF CRUSHED STONE AND 305mm OF GRANULAR MATERIAL COMPACTED AT 90% P.M.3.WOVEN STABILISATION FABRIC 300 WHTM IS CONSIDERED UNDER ALL CHAMBERS WITH WATER INTAKE (OVER A LENGTH OF 4.57M) AS WELL AS THE CHAMBER INCLUDING AN4.ACCESS WELL. (WHEN THE ACCESS WELL IS INSTALL ON THE END CAP, THE WOVEN STABILISATION FABRIC MUST BE UNDER THIS END CAP AND UNDER THE ADJACENT CHAMBER)
PART DESCRIPTION
A HYDROSTOR END CAP HS75
B HYDROSTOR CHAMBER HS75
C WOVEN STABILISATION FABRIC 300 WHTM
D SOLENO TX-90 SEPARATION NONWOVEN GEOTEXTILE, ABOVE, BELOW AND ON THE SIDES
E HYDROSTOR END CAP HS75 WITH WELDED ELBOW SOLFLO MAX 250mm FOR ACCESS WELL
F ADJUSTABLE FRAME AND COVER 250mm
G PVC PIPE ACCESS WELL 250mm(PROVIDED BY OTHERS)
H STD LENGTH 6m SOLFLO MAX 300mm
I ELBOW SOLFLO MAX 300mm
J CROSS SOLFLO MAX 300mm
K TEE SOLFLO MAX 300mm
L PRETREATEMENT UNIT
2021-01-12
SOLENO HYDROSTOR HS75 SYSTEM
THIS DOCUMENT IS THE PROPERTY OF SOLENO. IT MAY NOT BE REPRODUCED OR RETRANSMITTED TO ANYONE WITHOUT EXPLICIT WRITTEN CONSENT.