    PINZA AMPERIMETRICA

    PINZA AMPERIMETRICA / CLAMP METER / PINCE AMPÉRE-MÉTRIQUE

  • 8/17/2019 Pinza Amperimetrica

    2/11

     

    PINZA AMPERIMÉTRICA

    PARTES DE LA PINZA

    1. Pinza transformadora

    2. Disparador

    3. Interruptor “Data Hold”

    4. Interruptor “Peak Hold” (Valor de Pico)

    5. Ruleta de funciones

    6. Pantalla LCD

    7. Terminal “V/ Ω/Hz”: terminal de salida para medir el voltaje, la

    resistencia y la frecuencia.

    8. Terminal “COM”: terminal de corriente. Este es terminal de

    entrada negativo para todas las medidas excepto la corriente.

    9. Correa-muñequera anticaída

    10. Barrera protectora

    CARACTERÍSTICAS TÉCNICAS

    1. Característ icas generales

    Máxima apertura de la pinza: 32 mm

    Pantalla:LCD digital 3 1/2“, con indicador de polaridaddigital

    Método de medida: Sistema de conversión A/D integrado

    Protector de sobrecarga: Protección hasta 500V AC.

    Función DATA HOLD:La permanencia de los datos de la pantalla seconsigue pulsando alternativamente elpulsador “D.H”.

    Función PEAK HOLDFunción de máximo para visualizar enpantalla únicamente el valor máximo medidodesde la activación de la función

    Indicador de batería baja:El símbolo es visualizado cuando el voltaje dela bateria cae por debajo del nivel operativo.

    Carga de la batería: 9V alcalina o batería de carbono-zinc

    Humedad y temperatura operativa: 0ºC – 50ºC; max. RH: 80%Humedad y temperatura dealmacenamiento:

    -20ºC – 60ºC; max. RH: 80%

    Dimensiones: 205 x 71 x 38.8

    Peso: 272 gr.

    2. Especificaciones

    FUNCIÓN RANGO RESOLUCIÓN PRECISIÓN AC A 200A/600A 0.1A ±(1.5% rdg + 4 dgt)

     AC V 600V 1V ±(1.5% rdg + 4 dgt)

    DC V 600V 1V ±(1.0% rdg + 2 dgt)

    Resistencia 200Ω  1 Ω  ±(1.0% rdg + 2 dgt)

    Frecuencia 10MHz 0.001Hz ±(0.8% rdg + 2 dgt)

  • 8/17/2019 Pinza Amperimetrica

    3/11

     

    INTRODUCCIÓN

    La pinza es un instrumento de medida completamente portátil. Posee una pantalla digital LCD

    de 3 ½ “. Está diseñada para su uso en los lugares en los cuales se requiera realizar una

    buena medida de la corriente.

    Su diseño está concebido para la protección del usuario como medida de seguridad durante su

    uso, por medio de una carcasa fuerte que se caracteriza por su resistencia al impacto y al

    deterioro por sobrecaga electrónica. Además, incluye un relieve que actúa como barrera

    protectora para evitar descargas al usuario.

    INSTRUCCIONES

    1. Medida de corriente AC

    a. Elegir el rango correcto de ACA por medio de la ruleta (~600A o ~200A). Presionar

    el disparador para abrir la pinza de transformación y unirla la a un solo conducto.

    La pinza recoge la corriente alterna transmitida por el conducto.

    b. La figura inicial indica la variedad de funciones y el amplio rango que se puede

    seleccionar.

    c. La lectura debe visualizarse en la pantalla.

    d. Nota: Las pinzas deben estar completamente cerradas en el momento de la

    realización de la lectura.

    e. La lectura más precisa se obtendrá por medio del conducto central de la pinzatransformadora.

    2. Medida del voltaje AC

    a. Elegir el rango de la función ACV por medio de la ruleta (~600V).

    b. Conectar el cable negro en el terminal “COM” y el rojo en el terminal “V/Ω/Hz”.

     Ahora se puede colocar la sonda en los puntos de carga cuya diferencia de

    potencial se pretende medir.

    c. Para evitar problemas eléctricos o daños en el instrumento de medida, no intentar

    medir voltajes superiores a 600V AC.

    3. Medida del voltaje DC

    a. Elegir el rango de la función DCV por medio de la ruleta.

    b. Conectar el cable negro en el terminal “COM” y el rojo en el terminal “V/Ω/Hz”.

     Ahora se puede colocar el cable en los puntos de carga cuya diferencia de

    potencial se pretende medir.

    c. La polaridad del cable rojo debe estar indicada junto con el voltaje.

    d. Para evitar problemas eléctricos o daños en el instrumento de medida, no intentar

    medir voltajes superiores a 600V DC.

  • 8/17/2019 Pinza Amperimetrica

    4/11

  • 8/17/2019 Pinza Amperimetrica

    5/11

     

    MANTENIMIENTO

    El mantenimiento consiste en limpiar y reemplazar la batería periódicamente. El exterior de la

    pinza puede limpiarse con una tela seca para eliminar cualquier tipo de aceite o grasa. Nunca

    usar líquidos abrasivos o solventes.

    Reemplazar la batería cuando se visualice el símbolo indicativo en pantalla. Quitar la batería de

    la carcasa y reemplazarla por otra nueva.

    Para evitar problemas eléctricos, desconectar los cables de medición y cualquier señal de

    entrada antes de reemplazar la batería. Reemplazarla solo por baterías del mismo tipo.

  • 8/17/2019 Pinza Amperimetrica

    6/11

     

    DIGITAL CLAMP METER

    PARTS OF CLAMP METER

    1. Transformer jaw.

    2. Trigger.

    3. “Data Hold” push switch.

    4. “Peak Hold” push switch.

    5. Function know.

    6. LCD display.

    7. “V/  Ω/Hz” terminal: input terminal for measuring voltage,

    resistance and frequency.

    8. “COM” terminal: common terminal. This is negative (earth) inputterminal for all measurement modes except current.

    9. Drop-proof wrist strap.

    10. Barrier

    SPECIFICATIONS

    1. General feature

    Jaw opening capability: 32 mm

    Display:

    LCD digit 3 1/2“, with automatic polarity

    indicationMeasuring method: Dual-slope integration A/D converter system

    Over load protection Protected up to 500V AC RAMS

    DATA HOLD function:The hold and release for all display data isperformed alternatively by “D.H” push switch.

    Low battery indication:The symbol is displayed when the batteryvoltage drops below accurate operating level.

    Power supply: 9V Alkaline or carbon-zinc battery

    Operating temperature and humidity: 0ºC to 50ºC; 80% max. RH

    Storage temperature and humidity: -20ºC to 60ºC; 80% max. RH

    Dimensions: 205 x 71 x 38.8

    Weight: 272 gr.

    3. Specifications

    FUNCTIÓN RANGE RESOLUTIÓN ACCURACY AC A 200A/600A 0.1A ±(1.5% rdg + 4 dgt)

     AC V 600V 1V ±(1.5% rdg + 4 dgt)

    DC V 600V 1V ±(1.0% rdg + 2 dgt)

    Resistance 200Ω  1 Ω  ±(1.0% rdg + 2 dgt)

    Frequency 10MHz 0.001Hz ±(0.8% rdg + 2 dgt)

  • 8/17/2019 Pinza Amperimetrica

    7/11

     

    INTRODUCTION

    This clamp meter is completely portable, 3 ½ digit LCD display meter. It is designed to use in

    laboratory, field servicing, at home, or under any circumstance where high current

    measurement is required.

    This device is built with a finger guard design which ensures safety operating; a rugged case

    that is shock resistant; and electronic overload protection for all function and range.

    In addition, a carrying case is available for easy portability of the device, avoiding damage.

    INSTRUCTIONS

    1. AC Measuring current

    a. Set function knob to the proper ACA Range (~600A o ~200A). Press the trigger

    to open the transformer jaws and clamp on to one the transformer jaws and

    clamp on to one conductor only. The transformer jaws pick up the AC current

    flowing through the conductor.

    b. The figure indicates over range situation and the higher range has to de

    selected.

    c. The reading will be indicated on the display.

    Note: Jaws should be completely closed taking reading. The most accurate reading will

    be obtained by the conductor across center of the transformer jaws.

    2. AC Voltage measurement

    a. Set the function knob to the ACV range (~600V).

    b. Connect the black test lead to the “COM” terminal and red test lead to the

    “V/Ω/Hz” terminal. You can now place the test probes to the source or load

    under measurement.

    To avoid electrical shock, hazard or damage to the meter, do not attempt to

    measure voltage that might exceed AC 600V RMS.

    3. DC Voltage measurement

    a. Set the function knob to the DCV range

    b. Connect the black test lead to the “COM” terminal and red test lead to the

    “V/Ω/Hz” terminal. You can now place the test probes to the source or load

    under measurement.

    c. The polarity of red lead connection will be indicated along with the voltage

    value.

    To avoid electrical shock, hazard or damage to the meter, do not attempt to

    measure voltage that might exceed DC 600V.

  • 8/17/2019 Pinza Amperimetrica

    8/11

     

    4. Resistance measurement

    a. Set the function knob to the “ 200Ω” range.

    b. Connect the black test lead to the “COM” terminal and red test lead to thecircuit to the “V/Ω/Hz” terminal.

    c. Verify that the power to the circuit under test is off. Connect test lead to the

    circuit to make measurement.

    Note: If the resistance being measurement exceeds the maximum value of the range

    selected or the input is not connected, an over range indication “1” will be displayed.

     Attempting resistance or continuity measurements on live circuits can cause electrical

    shock, damage to the device and damage to the equipment under test. Resistance

    measurement must be made on de-energized circuit.

    5. Continuity test

    a. Set the function knob to the “ 200Ω” range.

    b. Connect the black test lead to the “COM” terminal and red test lead to the

    “V/Ω/Hz” terminal.

    c. Connect the test probes across two points of the circuit under testing. If

    continuity exists, BUZZER will sound.

    6. Frequency measurement

    a. Set the function knob to “Hz” range.

    b. Connect the black test lead to the “COM” terminal and red test lead the

    “V/Ω/Hz” terminal.

    c. Connect the probes to measuring source or load under testing and reading

    displayed value.

    d. Do not apply more than 250V RMS to input.

    e. Signal voltage to be measured must be > 1.0V.

    SAFETY INFORMATION•  Protection against the damage of electric shock.

    •  Never exceed the protection limit values indicated in the specifications for each range of

    measurement.

    •  When the device value scale to be measurement circuit, do not touch unused terminals.

    •  When the value scale to be measured is unknown, set the range selector at the

    highest position.

    •  Before rotating the selector change function, disconnect test leads from the circuit under

    testing.

  • 8/17/2019 Pinza Amperimetrica

    9/11

     

    •  Never perform resistance measurements on live circuits.

    •  When the jaw opening and to the conductor under testing, your fingers must keep

    behind the barriers indicator.

    •  Never ground yourself when taking electrical measurement, do not touch exposed metal

    pipes, outlets, mixtures, etc., which might be at ground potential. Keep your body

    isolated from ground by using dry clothing, rubber shoes, or any approved insulating

    material. Utilizar ropa seca, calzado de goma o cualquier material aislado

    apropiadamente.

    MAINTENANCE

    Maintenance consists of periodic cleaning and battery replacement. The exterior of the meter

    can be cleaned with a dry clean cloth to remove any oil, grease or grim. Never use liquid

    solvents or abrasives.

    When the meter displays the sign, the battery must be replaced to maintain proper operation.

    Remove the battery cover of case, replace the exhausted battery with new one.

    To avoid electrical shock, disconnect the test leads and any input signals before replacing the

    battery. Replace only with same type of battery.

  • 8/17/2019 Pinza Amperimetrica

    10/11

    SPAIN

    - ARTICULO:.....................................................................................................

    - Nº DE SERIE:..............................

    - DISTRIBUIDOR:..............................................................................................

    - PAIS:........................................... TELEFONO:......................................

    - FECHA DE VENTA:......................................

    - NOMBRE DEL COMPRADOR:.......................................................................

    - TELEFONO DEL COMPRADOR:...................................

    EGA MASTER GARANTIZA AL COMPRADOR DE ESTA MAQUINA LA GARANTIA TOTAL(DURANTE 12 MESES), DE LAS PIEZAS CON DEFECTOS DE FABRICACION.ESTA GARANTIA NO CUBRE AQUELLAS PIEZAS QUE POR SU USO NORMAL TIENEN UN DESGASTE.

    PARA OBTENER LA VALIDEZ DE LA GARANTIA , ES ABSOLUTAMENTE IMPRESCINDIBLE QUE COMPLETE Y REMITA ESTE DOCUMENTO A EGA MASTER , DENTRO DE LOS SIETE DIAS A PARTIR DE LA FECHA DE COMPRA.

    (EJEMPLAR PARA EGA MASTER)

    CERTIFICADO  DE  GARANTIA

    SELLO DEL DISTRIBUIDOR

    - ARTICULO:.....................................................................................................

    - Nº DE SERIE:..............................

    - DISTRIBUIDOR:..............................................................................................

    - PAIS:........................................... TELEFONO:......................................

    - FECHA DE VENTA:......................................

    - NOMBRE DEL COMPRADOR:.......................................................................

    - TELEFONO DEL COMPRADOR:...................................

    EGA MASTER GARANTIZA AL COMPRADOR DE ESTA MAQUINA LA GARANTIA TOTAL(DURANTE 12 MESES), DE LAS PIEZAS CON DEFECTOS DE FABRICACION.ESTA GARANTIA NO CUBRE AQUELLAS PIEZAS QUE POR SU USO NORMAL TIENEN UN DESGASTE.

    PARA OBTENER LA VALIDEZ DE LA GARANTIA , ES ABSOLUTAMENTE IMPRESCINDIBLE QUE COMPLETE Y REMITA ESTE DOCUMENTO A EGA MASTER , DENTRO DE LOS SIETE DIAS A PARTIR DE LA FECHA DE COMPRA.

    (EJEMPLAR PARA EL CLIENTE)

    CERTIFICADO  DE  GARANTIA

    SELLO DEL DISTRIBUIDOR

    .......................................................................................................................................................................................................................................................................................................

    SPAIN

  • 8/17/2019 Pinza Amperimetrica

    11/11

    ........................................................................................................................................................................................................................................................................................................

    - ITEM:..............................................................................................................

    - SERIE Nº:..........................................

    - DISTRIBUTOR:...............................................................................................

    - COUNTRY:......................................... PHONE:.......................................

    - SALE DATE:.......................................

    - BUYER NAME:................................................................................................

    - BUYER PHONE:.................................

    EGA MASTER GUARANTEES TO THE BUYER OF THIS MACHINE THE TOTAL WARRANTY(DURING 12 MONTHS), OF THE PIECES WITH MANUFACTURING FAULTS.THIS GUARANTEE DOES NOT COVER THOSE PIECES WORN OUT DUE TO A NORMAL USE.

    IN ORDER TO OBTAIN THE VALIDITY OF THIS WARRANTY , IT IS ABSOLUTELY NECESSARY TO FULFILL THIS DOCUMENT AND RESEND IT TO EGA MASTER WITHIN 7 DAYS FROM SALE DATE.

    (COPY FOR EGA MASTER)

    GUARANTEE

    CERTIFICATE

    DISTRIBUTOR STAMP

    SPAIN

    - ITEM:..............................................................................................................

    - SERIE Nº:..........................................

    - DISTRIBUTOR:...............................................................................................

    - COUNTRY:......................................... PHONE:.......................................

    - SALE DATE:.......................................

    - BUYER NAME:................................................................................................