01 FOX515_Integration_2010-02-08

89
© ABB Group February 4, 2011 | Slide 1 Réseau Télécoms SONELGAZ Intégration & Gestion des FOX515

description

FOX FORMATION

Transcript of 01 FOX515_Integration_2010-02-08

Page 1: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 1

Réseau Télécoms SONELGAZ Intégration & Gestion des FOX515

Page 2: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 2

AGENDA du 8 février 2011

Introduction FOX515 (Base installée et modules/services supplémentaires)

Modules optiques

Téléphonie

Données numériques

Téléprotection

Ethernet

Introduction & Informations des MUX du réseau Sonelgaz

Intégration FOX515 Exemples

Système de gestion (NMS) FOXMAN-UN

Discussion et Conclusions

Page 3: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 3

FOX515 Base installée/livrée totale 339 (12/2010)

Page 4: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 4

FOX515 Concept

Ce qui rend le FOX 515 une vraie plate-forme pour les sociétés de service publiques c'est…

… l'intégration de tout types de modules de transmission et de téléprotection

… la possibilité des cross-connexion internes entres les différents modules de transmission… la grande flexibilité

… la gamme exhaustive de types de modules

… redondance de la CPU et de l’alimentation

Page 5: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 5

FOX515 Concept:

Concept Mécanique:

21 positions/slots pour modules, inclus alimentation et unité centrale

Version 19”- ou ETSI

Très haute fiabilité

Basé sur des standards internationaux (ITU-T, IEC, IEEE, EN, ETS)

Compatibilité Electromagnétique:

Un rail pour la mise à la terre permet une propre protection.

Le couvercle avant assure la protection EMC

Testé par des laboratoires indépendants (KEMA)

Page 6: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 6

Access Bus

SBUS

PBUS

UBUS 4 Hwy.s

SBUS

Power Supply Unit POSUM

CU CU

21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

UBUS 4 Hwy.s

CU = Control Unit

Sector“A“ Sector“B“

Page 7: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 7

Structure Bus Complète

GECOD UNIDA TEBIT OTERM EXLAN NEMCA

8x2Mb/s U-BUS

128x2Mb/s P-BUS

SYNACSYNAC SYNVA

2xVC-4 S-BUS Slot 2..9>Sector ”A”

2xVC-4 S-BUS Slot 15..20>Sector “B”

SYNOTSYNIFSYNIC

TUPON

LOMIx PHLCxSUBHx

SYNVA

COBU<X>

SYNAM SYNIO

DATAx

SYNUF NEBRx

LAWA4ETER1STICx

SYN4E SYN4E

NEMSG

OPTIF

Page 8: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 8

Unité de contrôle: COBUx

Gère la synchronisation

SDH/ PDH synchronisation

Entrées et sorties synchronisation

Contient une base de données du système (logiciel et configuration)

Fournit l’interface de gestion (F, Qx, ECC)

Contient un routeur IP pour le ECC (canal de communication intégré)

Connecte UBUS et PBUS

Intègre 4 entrées d’alarmes

Fournit 2 sorties d’alarmes

Contient un générateur / analyseur de signaux intégré pour la diagnostique

Permet la configuration redondante...

Page 9: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 9

Protection MUX FOX515

Page 10: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 10

Modules SDH SYN4E module optique avec 4 x cages SFP

4 x cages pour unités SFP pour: 4 x STM-1 (155Mbit/s):

S-1.1, L-1.1, L-1.2, X.1.2, U-1.2 et CWDM Max. 2 x STM-4 (622Mbit/s):

S-4.1, L-4.1, L-4.2, X.4.2 et CWDM

Nombre des circuits: 2 circuits optique STM-4 or STM-1 2 circuits optique STM-1 4 circuits FastEthernet & Gigabit Ethernet (électrique RJ45)

Connecteur Optique Type: LC/PC

Fonctionnalités principales du 10/100/1000Base-T Ethernet:

Modes: Auto-négociation, semi duplex et duplex parfait

Flow control, Trame jusqu’à 1600 bytes

EoS over VC-4, VC-3 and VC-12

VCAT (Virtual Concaténation)

LCAS (Link Capacity Adjustment Scheme)

Page 11: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 11

Distances, exemple pour STM-1:

Court: 12dB for up to 20km S-1.1 on 1310nm

Medium: 20dB for up to 60km L-1.1 on 1310nm

Long: 28dB for up to 100km L-1.2 on 1550nm

Extra-long: 32dB for up to 120km V-1.2 on 1550nm

Ultra-long: 50dB for up to 160 … 200km U-1.2 on 1550nm

SFP: Small Form Factor Pluggable transceiver

FOX515: Interface Optique utilisant technologie SFP

Page 12: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 12

2 x STM-1155Mbit/s

4 x Ethernet, électrique 10 – 100 – 1000Mbit/s

Capacité «Add-Drop» locale:

STM-4 ou STM-1 STM-4 ou STM-1

SDH Ethernet4 x E1 (2Mbit/s)to / from PBUS

3 x VC-3, 63x VC-12to / from SBUS

PDH SDH

électrique (RJ45)Optique

Modules SDH SYN4E module optique avec capacité STM- 1/4

S-BUS(FOX515 internal )

P-BUSFOX515 internal)

Page 13: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 13

voice

legacy data

STM-1 STM-1

N x E1 Ethernet/IPTraffic

Réseau STM-1

FOX515 Extension: Du STM-1 …

STM-1

Page 14: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 14

FOX515 Extension: … au STM-4 …

voice

legacy data

STM-1 STM-1

N x E1 Ethernet/IPTraffic

Réseau STM-4

STM-1

En changeant le SFP

Page 15: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 15

NEMSG 2/4 fils E&M 8 x interfaces fréquence audio (AF)

300 Hz ..3.4 kHz

Conférence vocale

Compatible avec NEMCA

EXLAN (Exchange Line Analogue)

12 interfaces de autocom pour des connections d'abonné

simule un téléphone vers l’autocom

SUBHx (Subscriber high density line card) 10/ 30 interfaces 2-fils pour des connections d’abonné

Le FOX515 permet l'extension d'une ligne d'abonné 2-fils à travers un réseau de transmission en utilisant les modules EXLAN (coté PAX) et SUBHx (coté abonné)

Modules Phonie

Page 16: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 16

Modules Phonie Application: Liaison prédéterminée (Hot Line) et abonné éloigné

Direct Hot Linewithout PABXSUBH1 – SUBH1

Remote SubscriberEXLAN – SUBH1

Page 17: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 17

SYNxxSTM1

STM1

VC 4

VC 4

NEMCANEMSG

64k

FOX 515

SYNxx STM1

VC 4

VC 4

NEMCANEMSG

64k

FOX 515

4 Wire E&M

Modem

2/4 Wire

Modem

4 Wire E&M

2/4 Wire cross-connect cross-connect

Connectivityover SDH/PDH

PABXe.gIS30x0/ IPS2000 A

TU-E

M

PABXe.gIS30x0/ IPS2000A

TU-E

M

Modules Phonie Application: 4-fils E&M et VF Modem

Page 18: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 18

DATA4/DATAR V.24/V.28 (4 interfaces) 4x V.24/V.28, RS-232 0...0.3kbit/s transp (V.110) 0.6kbit/s...38.4kbit/s sync/async (V.110) 1x 10/100BaseT Bridge

DATA3/DATAV V.35 (4 interfaces) 4x V.35 48, 56, nx64kbit/s (n=1-31) sync 0.6kbit/s...38.4kbit/s sync/async (V.110) 1x 10/100BaseT Bridge

DATA1/DATAT X.24/V.11 (4 interfaces) 4x X.24/V.11 48, 56, nx64kbit/s (n=1-31) sync 0.6kbit/s..38.4kbit/s sync/async (X.30) 1x 10/100BaseT Bridge

DATA5/DATAS universel (4 interfaces) 4x V.24/V.28, V.35, X.24/V.11, RS485 software programmable 1x 10/100BaseT Bridge

LAN Port 10/100BaseT

Module Données Numériques: DATA<X>

Page 19: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 19

Module Données Numériques: DATA<X> (Version HW R1A)

Unit NameDCE

Interface Type

Network Functions

X.21/V.11 V.35 V.24/V.28 LAN 10/100BaseTBridging, (IF-4 only) RS485 Subrate Multiplexing

4 IF 4 IF 4 IF 1 IF 4 IF 1+1 Path Protection

Performance Monitoring Time Slot

Point to Multipoint Application

DATAS 512 yes yes yes yes yes yes

DATA5 513 yes yes yes yes yes no

DATAV 514 no yes no yes no yes

DATA3 515 no yes no yes no no

DATAR 516 no no yes yes no yes

DATA4 517 no no yes yes no no

DATAT 518 yes no no yes no yes

DATA1 519 yes no no yes no no

Page 20: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 20

Module Données Numériques DATA<X>: Application Système Scada

Protocole 101: Interface données électrique

Protocole 104: Interface LAN

Page 21: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 21

PDH LOMI4/LOMIF

Interfaces numériques 4 ou 8 * 2Mbit/s avec (G.704) ou sans trame (G.703)

Accès PBUS

jusqu'à 16 modules par FOX515 (cela fait un total de 128x 2Mbit/s par bâti)

Impédance de 75 ou 120 , défini par le type de câble et connecteur

Contient sa propre part de brasseur numérique

Page 22: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 22

LOMI4/LOMIF: Application Accès (Tributary)

Les Interfaces numériques 2 Mbit/s sont utilisés pour des différentes applications:

FOX515 est utilisé comme MUX de transport: Interconnexion aux appareils terminaux (PABX, router etc.)

SBUS

SYNIOSTM-1

VC 4

LOMIF

2M

PBUS

2 Mbit/sG.703/704

VC 4

STM-1

VC12

Page 23: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 23

LOMI4/LOMIF: Application Transport (Aggregate)

FOX515 est utilisé comme MUX d’accès: Interconnexion au MUX de transport (FOX515H, FOX660 etc.)

n lines2Mbit/s

STM-4

STM-4 STM-16

Mux

LOMIF

FOX 515

STM-16Mux

STM-16Mux

LOMIF

FOX 515

LOMIF

FOX 515

STM-4

STM-4

STM-4

n lines2Mbit/s

STM-16Mux

LOMIF

FOX 515

n lines2Mbit/s

STM-16Mux

LOMIF

FOX 515

G.704 G.704

G.704

G.704 G.704

G.703

G.703G.703

G.703 G.703

Page 24: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 24

Protection différentielle: OPTIF module 4 x interfaces optique selon IEEE C37.94 (nouveau

standard)

Connexion directe en optique avec RED670 (relais de protection ABB)

Autres fournisseurs qui supportent IEEE C37.94

Modules Téléprotection

Téléprotection: TEBIT module 4 x interfaces numériques pour la transmission des signaux à

très haute fiabilité (4 commandes bidirectionnels) Support:

Déclanchement indirect (permissive) Déclanchement direct Blocage

Optimisé pour vitesse- ou sécurité Temps de transmission réduit Option: 8 x interfaces binaires (8 contacts bidirectionnels)

Page 25: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 25

4 x commandes téléprotection Transmission des signaux à très haute fiabilité

Câbles directement connecté (48 – 220DC) Transmission bidirectionnel Optimisé pour vitesse ou sécurité Temps de transmission réduit

Sorties d’alarmes Event Recorder, peut être synchronisé avec un

récepteur GPS Fonctionnalités spéciales:

Supervision du temps de transmission Commutation de protection de chemin 1+1

rapide (< 4 ms) Test en boucle Adressage des commandes pour sécurité

additionnelle Option: 8 x interfaces binaires (8 contacts

bidirectionnels)

Module de Téléprotection: TEBIT

Page 26: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 26

TEBIT: Avantages pour les Téléprotection

Fiabilité Intégré dans un seul équipement – moins de hardware, moins de câblage et

une disponibilité du système plus élevée

Rapide protection de chemin 1+1 pour chaque direction (au niveau 64kbit/s).

Sécurité ABB Safety Frame Concept (assigne une adresse pour chaque liaison

Test en boucle intégré

Supervision d’un Système de Gestion (FOXMAN, UCS-T)

Un réseau intégré Canal de téléprotection est complètement géré

Délai de transmission de commande: Typiquement < 5 ms Commutation de protection de chemin 1+1 rapide: Typiquement > 4 ms

Beaucoup plus rapide que les recommandations ITU-T pour des systèmes SDH < 50 ms

Page 27: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 28

Telecommunication System

Teleprotection System / Teleprotection Function

Protection System / Protection Function

OLT

E

MU

X

OLT

E

MU

X Protection Relay

Protection Relay Convertisseur Convertisseur

Soustation AHV-line

Soustation B

Protection différentielle : Solution traditionnelle

Page 28: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 29

Protection différentielle / OPTIF

un système

FOX 515

FOX 515

OPT

IF

OPT

IF

NMS: Système de Gestion

Relais de Protection

Relais deProtection

Soustation ALigne HT

Soustation B

IEEE C37.94

IEEE C37.94

INTÉGRATION totale dans le système de télécommunication

Entièrement inclus dans le système de gestion FOXMAN-UN dépannage rapide

Moins d’interfaces, moins d’équipement DISPONIBILITÉ de système plus élevée!

Page 29: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 30

Protection différentielle / OPTIF

4 x Ports ANSI/IEEE C37.94

Relais de Protection ABB RED670

Relais de tiers avec interface C37.94

Téléprotection NSD570 avec module G1LOa

4 x Ports optiques ABB 64kbit/s sur 1310nm MM

Relais ABB REL316, REL551, REL561

Téléprotection NSD570 avec module G1LO

FOX6Plus

1 x Port Ethernet électrique/optique

10/100BaseT ou 100BaseFX

Protection 1+1 via N x 64kbit/s pour commutation SYMÉTRIQUE de la voie Tx & Rx

Page 30: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 31

Protection différentielle / OPTIF

ANSI / IEEE C37.94 / Faits et Avantage : C’est une nouvelle norme pour les relais de protection (différentielles)

Tous les nouveaux relais d’ABB (e.g. RED 670) soutiennent cette norme

Beaucoup d'autres fournisseurs de relais de protection soutiennent également cette norme C37.94: e.g.: RFL, GE, Alstom

1 - 12 intervalle de temps par canal: (64 – 768 kbit/s)

Médias de raccordement: Fibre Optique, multi-mode (Plusieurs fabricants soutiennent également la fibre mono-mode)

Débit binaire: 2Mbit/s, ITU-T G.703 avec structure de verrouillage de trame spécialisée

Avantage: Cette norme offre

Interconnexions simples et sûres

Interopérabilité entre le relais et l’équipement de transmission

Page 31: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 32

OPTIF Application: Relais Protection Différentielle

Réseau Communication

IEEEC37.94

FOX515 avec module OPTIF

FOX515 avec module OPTIF

Ligne HT

VoieDonnés

Voie

Soustation „A“ Soustation „B“

e.g. STM-1ou STM-4

RED REDIEEEC37.94

4x 4x

Donnés

Page 32: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 33

OPTIF Application: Interconnexion équipement (ABB)

REL / NSD

FC/PC ou E2000Connecteur

SFP avec LC-Connecteur

Fibre mono modeABB Safety Frame Concept Réseau SDH:

STM-1 ou STM-4

Armoire RelaisArmoire Telecom

FOX 515

soustation

ODF

FC/PC ou E2000Connecteur

REL316

REL551 REL561

Armoire Telecom

B

A

FOX 515

Réseau SDH:

STM-1 ou STM-4

soustation

SFP avec LC-Connecteur

NSD570

Fibre mono modeABB Safety Frame Concept

Page 33: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 34

Protection différentielle / OPTIF

S/S A S/S B

RED670

IEEEC37.94

RED670

IEEEC37.94

155 ou 622Mbit/s

FOX515FOX515

Indication LED: Statut, alarme

4 x C37.94 avec cages SFP

1x Ethernet

électrique RJ45

optique IF 100Base-FX

Retard de Transmission Td =2

(T1 + T2)RED670 avec temporisation d’écho:

T1

T2

Compensation de temps pour Td: jusqu’à 20ms Mesure de retard (boucle): chaque 5ms

Page 34: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 35

Protection différentielle / OPTIF

Indication LED: Statut, alarme

4 x C37.94 avec cages SFP

1x Ethernet

électrique RJ45

optique IF 100Base-FX

Pour éviter des faux déclanchement après la commutation de la 1ère voie à la voie de secours, la protection différentielle exige:

Commutation (symétrique) bi-directionnelle des deux fibres (Rx et Tx)

S/S A S/S B

IEEEC37.94

IEEEC37.94

155 ou 622Mbit/s

1ère voie FOX515FOX515

Voie de secours

Page 35: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 36

Protection du chemin

Station A Station B

Principal

secours

RELREL

SANS commutation (symétrique) bi- directionnelle des deux fibres (Rx et Tx)!

Multiplexeur typique:

Transmission redondante utilisant protection du chemin (Nx 64kbit/s)

Page 36: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 37

OPTIF (C37.94): Protection du chemin symétrique

MAIN

standbyFOX515 FOX515

FOX515FOX515FOX515

FOX515

FOX515 / OPTIF: (C37.94 interface optique)

Transmission redondante utilisant protection du chemin (Nx 64kbit/s):

DIFFREL

DIFFREL

Commutation symétrique (Bidirectionnelle) !

=> Même délais pour Tx et Rx

Station A Station B

Principal

secours

RELREL

SANS commutation (symétrique) bi- directionnelle des deux fibres (Rx et Tx)!

Multiplexeur typique:

Transmission redondante utilisant protection du chemin (Nx 64kbit/s)

Page 37: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 38

Protection différentielle / OPTIF

Fiabilité Intégré dans un équipement simple - moins de matériel, moins

de câblage et disponibilité de système plus élevée

Commutation symétrique permet un routage de canal redondant même pour des applications de protection différentielle

Sécurité Supervisé par système de gestion centralisé

Un réseau intégré Canal de téléprotection entier est contrôlé

Boucle de teste pour la maintenance et localisation du défaut

Commutation rapide: Typiquement < 25 ms A capacité d’évolution

Flexibilité en employant des SFP

Port optique/électrique Ethernet pour une future migration à CEI61850

Page 38: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 39

Intégration de la Vidéo et de la Téléphonie IP

FOX515: Modular Concept Ethernet/ IP interfaces

Ethernet/IP interfaces for connecting various IP applications such as energy meters, VoIP phones or cameras

Ethernet over SDH or PDH services

1 to 8 physical ports

10/100BaseT, 100Base/FX, 1000BaseSX/LX ports

Point – point Ethernet tunnel

L2 Switching (RSTP)

L3 routing (OSPF)

Power over Ethernet

Page 39: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 40

Provides Ethernet over PDH and Ethernet over SDH (EoS) functionality

4 x 10/100BaseT Ethernet front ports

Up to 64 P-BUS connection points

Backplane access 16 x E1 P-BUS

PPP termination (N x 64kbit/s and 2Mbit/s).

HDLC termination (N x 64kbit/s and 2Mbit/s)

Ethernet features

VLAN (IEEE 802.1Q)

VLAN Q in Q

STP/ RSTP (IEEE 802.1w)

Multiple switching instances

QoS and Traffic Management.

ETER1 Release 2

R2: Dynamic (OSPF v2) and static routing

Ethernet / IP Modules ETER1: L2-Switch, with 16 x 2Mbit/s P-BUS access

Page 40: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 41

Ethernet / IP Modules ETER1: Multiple bridging instances

ETER1 ETER1

For each service own logical bridge is defined in ETER1 module

Multiple bridging instances allows to separate different Ethernet/ IP applications completely

PDH/ SDH Network

Page 41: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 42

Ethernet / IP Modules ETER1 Application Topologies

Topologies réseau ETER1 permet plusieurs

topologies réseau comme… ...configurations étoiles ...configurations anneaux ...réseaux linéaires

Intégration facile de: - Systèmes contrôles de postes - LAN`s pour RTU - LAN`s pour ordinateurs - LAN`s pour supervision (vidéo)

Page 42: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 43

Ethernet / IP Modules ETER1 SCADA application

ETER1 caters for various network topologies such as... ...star configurations ...ring configurations ...linear networks

Offers integrated solution for IEC 60870-5-104 (IEC 60870-5-101 supported with DATAx)

Redundancy in control center via redundant FOX 515 or redundant power supply/control board

Connection redundancy via LAN ring configuration (Router) SDH ring configuration (Bridge)

Page 43: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 44

IP-based SCADA Solution

Connect RTUs with nx64kbit/s to an ETHUB or ETER1

Connect Control HW to ETER1 in Control Center

Easy to maintain & extend

ETER1ETER1ETER1

Page 44: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 45

Video over IP Solution

Connect Cameras with : nx64kbit/s to ETHUB, LAWA, ETER1 or nx2Mbit/s to NEBRO

Connect Control HW to LAWA or NEBRO in Control Center

Up-to-date Video over IP solution

Page 45: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 46

Wide Area Networks (WANs)

Connect PC`s, Printers, Servers, IP Phones with:nx64kbit/s to ETHUB, LAWA4, ETER1 or nx2Mbit/s to NEBRO

No converter boxes needed, Integrated into one management

Easy to maintain & extend

Page 46: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 47

6 Front ports 4x Ethernet: 10/100BaseT 2x GbE: 100Base-FX or

1000Base-SX/LX

L2 switching including

STP/ RSTP (IEEE802.1w)

VLAN (IEEE802.1p/q)

Provides Ethernet over SDH (EoS) GFP Generic Framing Procedure

ITU-T G.7041 LCAS Link Capacity Adjustment Scheme,

ITU-T G.7042 VCAT Virtual Concatenation

Direct S-BUS access Max. 63 x VC-12 8 x ports on S-BUS

Ethernet/ IP Modules NEBRO: Ethernet / GbE interface with L2 switching

Page 47: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 48

NEBRO allow interconnection of different sites with different traffic priorities

RSTP (Rapid Spanning Tree Protocol) can be used to avoid loops when using redundant paths

VCAT and LCAS allow concatenation and dynamic allocation of bandwidth without loss of traffic when bandwidth is added/removed

Ethernet/ IP Modules NEBRO: Application

Page 48: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 49

Video system: Services Remote access via IP / SDH

Page 49: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 50

Integrated into FOX515

NEBRE is powered, configured and supervised from FOX515 using UCST.

Same front-connections as NEBRO 4 x RJ45 electrical, 2x optical SFP)

Functions:

VLAN tag stacking (Q-in-Q)

Wire-speed Ethernet switching (Supporting baby jumbo frames 1600Bytes)

VLAN tagging, bridging and trunking

Traffic prioritization according to IEEE 802.1p

Spanning Tree Protocol (STP) and Rapid STP

Applications:

Adds L2 switching function to SYN4E

Supervised L2 GbE-switch in FOX515 networks

Ethernet/ IP Modules NEBRE: Ethernet / GbE switch (no S-BUS connection)

Page 50: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 51

8 x 10/100/1000 Mbit/s Ethernet front interfaces:

2 x SFP 1000Base-SX/LX/TX trunk ports

6 x RJ-45 10BaseT or 100Base-TX access ports

No BUS access on FOX515

Power over Ethernet functionality

In total max. 60W can be allocated to the 6 access ports

Either 2 x PoE+ (27W) or 4 x PoE as per IEEE802.3af (15W) or 60W distributed over all 6 ports

2 x PoE (up to 15W not isolated) 10/100Mbit/s

SWITE: Main Features

L2-switching including VLAN Q in Q

STP and RSTP on trunk ports

Ethernet/ IP Modules SWITE: L2 switch with Power over Ethernet (PoE)

Page 51: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 52

SWITE

SWITE

SWITE

VLAN 10 VLAN 10

Anneau SDH avec RSTP

VLAN 30VLAN 20

Serveur SIP

VLAN 20 VLAN 20

VLAN 30 VLAN 30

Serveur Vidéo

Alimentation inutile ( PoE)

Ethernet/ IP Modules SWITE: Application PoE

Page 52: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 53

Supervision par Vidéo et Téléphonie IP

Ethernet Switch AFS650/655

DIN Rail mounted managed Ethernet Switch of utility grade (wall mounting possible)

Metal housing

Up to 10 FE ports (electrical, optical or SFP cages)

Up to 3 GbE ports (electrical, SFP or Combo ports)

Multimode and Single Mode versions available

Huge variety on optical ports: SFP cages, SC, ST, …

SFP’s in various versions available (MM, SM, single fibre)

24/36/48 VDC or 60/120/250 VDC, 110/230VAC Power supply, Redundant Power supply possible

CRA (Configuration Recovery Adapter) port for easy exchange of product

Page 53: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 54

Supervision par Vidéo et Téléphonie IP

Ethernet Switch AFS650/655

19” managed Switch of utility grade Metal housing, Ports on front or on rear (typical

substation config) Modular concept, 1 module for 2 ports needed, any

combination possible (expect GbE & PoE); in total 12 slots available

High port density Up to 28 FE ports (electrical, optical or SFP

cages) Huge variety on optical ports: SFP cages, SC,

ST,.., MM and SM SFP’s in various versions available (MM, SM,

single fibre) Up to 4 GbE ports (optical, electrical or combo

ports) Up to 4 Ports PoE

Low/ High Voltage as well as AC/ DC power supply, redundancy possible

CRA (Configuration Recovery Adapter) port for easy exchange of product

Page 54: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 55

FOX515 Base installée/livrée totale 339 (12/2010)

Page 55: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 56

FOX515 Base installée/livrée – Région d’Alger

2x

2x

3x

2x

2x

2x

2x

2x

Page 56: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 57

FOX515 Base installée – Situation actuel Exemple / Poste 60/30 kV Bab Ezzouar

E1

RS

232

Page 57: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 58

FOX515 Base installée – Situation optimisée Exemple / Poste 60/30 kV de Bab Ezzouar

RS

232

Page 58: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 59

Reroutage de certains canaux dans un MUX défectueux

Exemple Poste de Tiaret : FOX515 existant peut être

utilisé

Transférer les deux circuits RS-232 du MUX au FOX515

Rajout d’une DATA5 et LOMIF si redondance est requise

Prévoir un FOX515 au CRC d’Oran si pas déjà disponible

Paramétrie et mise en service du FOX515 à Tiaret et au CRC Oran

Backbone SDH STM-16

Metro 3000(STM-16)

3x STM-16

1x STM-4

3x STM-1

2x FE

3x E3

TIARET220/60kV

Metro 5000(STM-16)

4x STM-16

3x STM-4

10x STM-1

2x FE

6x E3

63x E1

SAIDA220/60kV

Metro 5000(STM-16)

6x STM-16

6x STM-4

10x STM-1

7x FE

9x E3

63x E1

OUED SLY220/60kV

FO / ~ 138 km FO / ~ 94 km

CR

C O

RA

N

CR

C O

RA

N

MUX(E1)

4W E&M

FXO / FXS

RS-485

RS-232

CCN

FOX515HE539253

2x NEMSG

EXLAN

2x SYN4E

5x TEBIT

DATA5

RS

-232

E1 / 2 Mbps

63x E1

RS-

232

E1

LOMIF

E1

Page 59: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 60

FOX515 Base installée – Optimisation du Réseau

LEGENDE :

DG : Direction GénéraleCNC : Centre National de ContrôleCNC-R : Centre National de Contrôle de RepliCRC : Centre Régional de ContrôlePCG : Poste de Commande Groupée

S : MUX SDH SAGEM (ADR2500)H : MUX SDH HUAWEI (OptiX xxxx)F : MUX PDH/SDH ABB (FOX515)NMS : Système de gestion ABB FOXMAN-UN

Kouba

PCGO. Fayet

S / H

Hydra

S / H CNC / CRC

S / H

PCGB. Mered

S

A. Benian

S

B. Aknoun

S / H

Aurassi

S / H

DG / CNC-R

S / H Tafoura

S

Amirauté

S

Alger PortH

Hamma

H Glaciere

S / H

El Harrach 1

PCGAlger Est

S / H

Si Mustapha

S

C. Djenet

S

Ain TayaF

F

4x F

3x F

F

2x F

7x F

2x F

2x F

F

Région d’Alger

H

PCGEl Khemis

2x F

HPCGBeroughia

F

PCGBouira

PCGDjelfa

S / H

H

PCGOued Sly

F H

Kherba

H

H

11x F

Ahmer El Ain

F

4x F

F

2x F

Ghrib

F

Bir Ghbalou

F

Ain Mrene

H

Arbaa

3x F

2x F

Meftah

H

3x F

Chlef 2

F

Dess. Cap Djinet

F

MohamediaBab Ezzouar

3x

2x F

Mustapha

2x

F

Réserve

F

Réserve

S

El Harrach 2

F

F

S

H

2x

2x

FRéserve

3x

FFutur Tonic

FDouaouda

2x2x FSidi Abdellah

2x

2x FMiyehTipaza 2x F

Kolea

F

Birtouta

FCherchel

FEl Afroun

FBlida

2x

2x

F

Onex

F

OnidF

2x

S. Rached

2x

F

Meramene

2x

FChlef 1

FDess. Tenes F

Tenes

F

F

Oued Fedda

Oum Drou

H

4x F

Mazafran 220 kV

3x F

Maza.60 kV

Aflou 2

Optimisation du Réseau :Rajout modules optiques SYN4E

aux FOX515 existants

Page 60: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 61

Intégration FOX515 au Backbone SDH STM-16

POSTE 400/220 kV DE AIN BEIDA (F’KIRINA)

AB

D /

220k

V -5

km

AB

D /

220k

V -5

km

5x E1

25x RS232

10x RS485

4x TELEPROT.

20x 2F/4F E&M

Equipement SDH / HUAWEI Type OSN 3500

Equipement PDH / ABB Type FOX515

5x E1

25x RS232

10x RS485

4x TELEPROT.

20x 2F/4F E&M

63x E1

10x STM-16

BIS

/ 40

0kV

-240

km

CH

F / 4

00kV

-15

0km

OA

T / 4

00kV

-12

7km

OSN 3500

FOX515 FOX515

4x FE

Page 61: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 62

Intégration & Optimisation FOX515 au Backbone Exemple Poste de KhenchelaDonnées

Page 62: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 63

Réseau Télécoms SONELGAZ Système de Gestion FOXMAN-UN/NV

Page 63: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 64

Système de gestion (NMS) / FOXMAN-UN (1) Exemple 1 / Poste de Aflou 220/60 kV

Page 64: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 65

Système de gestion (NMS) / FOXMAN-UN (2) Exemple 2 / Zone Industrielle d’Arzew PB 1 & 2

F

Réseau d’Oran

LEGENDE :

DG : Direction GénéraleCNC : Centre National de ContrôleCNC-R : Centre National de Contrôle de RepliCRC : Centre Régional de ContrôlePCG : Poste de Commande Groupée

S : MUX SDH SAGEM (ADR2500)H : MUX SDH HUAWEI (OptiX xxxx)F : MUX PDH/SDH ABB (FOX515)NMS : Système de gestion ABB FOXMAN-UN

OSN3500 livré dans le cadre du projet d’Arzew

FOX515 livré dans le cadre du projet d’Arzew

Région d’Oran

S

S / H

CRC OranS

Oran Ouest

Oran EstS

Zone d’Oran

SC.D.M.

S

Oran Sud

S

S

Ravin Blanc

Petit Lac

S

Zahana

S

Hassi Ameur

Backbone de l’Ouest(SDH STM-16)

H H

H

Marsat

ZI ArzewPB 1

ZI ArzewPB 2

H

3x F

2x F

FF

Fert

ial

F

Met

hano

lF

Am

o-O

rasc

F

Fert

alge

F

SPM

F

GP2

ZF

GL4

ZF

NA

F/R

AFF

F

Des

ydro

F

F

Asm

idal

F

FFF

Hel

ium

IIF

Am

mon

iac

F

GL2

ZF

GP1

ZF

L3Z

F

Res

érve

F

F

F

S / H

NMS

CNC Alger

OuS Khb Khm BeM OuF Kou

FOXMAN-UN/NVServeur

NMS

FOXMAN-UN/NVClient

H

F

Beni Saf

Page 65: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 66

Système de gestion (NMS) / FOXMAN-UN (3) Exemple 3 / Région d’Alger

LEGENDE :

DG : Direction GénéraleCNC : Centre National de ContrôleCNC-R : Centre National de Contrôle de RepliCRC : Centre Régional de ContrôlePCG : Poste de Commande Groupée

S : MUX SDH SAGEM (ADR2500)H : MUX SDH HUAWEI (OptiX xxxx)F : MUX PDH/SDH ABB (FOX515)NMS : Système de gestion ABB FOXMAN-UN

Kouba

PCGO. Fayet

S / H

Hydra

S / H CNC / CRC

S / H

PCGB. Mered

S

A. Benian

S

B. Aknoun

S / H

Aurassi

S / H

DG / CNC-R

S / H Tafoura

S

Amirauté

S

Alger PortH

Hamma

H Glaciere

S / H

El Harrach 1

PCGAlger Est

S / H

Si Mustapha

S

C. Djenet

S

Ain TayaF

F

4x F

3x F

F

2x F

7x F

2x F

2x F

F

F

Région d’Alger

H

PCGEl Khemis

2x F

HPCGBeroughia

F

PCGBouira

PCGDjelfa

S / H

H

PCGOued Sly

F H

Kherba

H

H

11x F

Ahmer El Ain

F

4x F

F

2x F

Ghrib

F

Bir Ghbalou

F

Ain Mrene

H

Arbaa

3x F

2x F

Meftah

H

3x F

Chlef 2

F

Dess. Cap Djinet

F

MohamediaBab Ezzouar

3x

2x F

Mustapha

2x

F

Réserve

F

Réserve

S

El Harrach 2

F

F

S

H

2x

2x

FRéserve

3x

FFutur Tonic

FDouaouda

2x2x FSidi Abdellah

2x

2x FMiyehTipaza 2x F

Kolea

F

Birtouta

FCherchel

FEl Afroun

FBlida

2x

2x

F

Onex

F

OnidF

2x

S. Rached

2x

F

Meramene

2x

FChlef 1

FDess. Tenes F

Tenes

F

F

Oued Fedda

Oum Drou

H

4x F

Mazafran 220 kV

3x F

Maza.60 kV

FOXMAN-UN/NVClient

FOXMAN-UN/NVServeur

CRC / CNC Alger

Aflou 2

NMS

Page 66: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 67

Intégration & Optimisation FOX515 au Backbone Exemple Poste de Khenchela

ECC

ECC

ECC

ECC

ECC

Système de Gestion (NMS)

Page 67: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 68

FOXMAN-UN Dispositifs

Système de gestion complet pour le FOX 515 et le FOX-U de legs

Vue graphique du réseau avec nombreuses fonctionnalités

Gestion compréhensive des alarmes

Accès direct de la configuration de tous les nœuds du réseau

Gestion du cheminement bout à bout

Intégration des objets "étrangers" pour la surveillance d'alarme et la gestion du cheminement

ALS (Serveur d’alarme) / Intégration de dispositif pour:

ETL600, NSD570, FOX660, FOX515H Alarme et démarrage du logiciel de configuration propriétaire (HMI, UCST, etc.)

Soutient l’accès à distance et serveurs redondants

S‘intègre dans des systèmes de gestion de niveau supérieurs

Fonctionne sur plateforme Linux

Aide «Online» détaillée

Page 68: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 69

Plate-forme

FOXMAN-UN R8C fonctionne sur

RedHat Enterprise Linux 5 (x86 Plate-forme)

Matériel recommandé: Postes de travail ou serveurs Dell

Page 69: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 70

FOXMAN-UN Architecture de Système

FOXMAN-UN consiste des composants suivants :

NEM Configurateur

NEM Navigateur de réseau

Agents

NEM Noyau avec base de données inclue

Paquet de gestion de réseau

Interfaces «North Bound» (e.g. SNMP)

Réseau

FOX515 et/ou FOX660

ALS

Dispositifs ALS:

ETL600 etc.

Page 70: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 71

Vue graphique de réseau

Vues géographiques et logiques du réseau possible

Bannière d’alarme pour montrer l'état global d'alarme du réseau

État d'alarme d'élément de réseau représenté par symbole coloré

Accès direct à tous les détails d'alarme, configuration de nœud (cheminement incl.) et vue de synchronisation de réseau

Page 71: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 72

Vue graphique de réseau « Screenshot NMS Ghana » Exemple : FOX515 et ETL600 gérés par FOXMAN-UN

Page 72: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 73

Gestion d’alarmes

Information d'alarme complète par

Bannière d’alarme

Colorisation du symbole de nœud

Liste d’alarme

Vue d'alarme du châssis

Historique des alarmes

Page 73: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 74

Gestion d’alarmes : Explorateur de réseau

Les couleurs de symbole représentent l'état global d'alarme des éléments de réseau

Des marqueurs indiquent les alarmes non quittancées

Les couleurs de la section représentent l'état d'alarme des liens physiques pour les raccordements optiques et électriques

Page 74: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 75

Gestion d’alarmes : Explorateur de réseau

Permet à l’opérateur de garder une vue d’ensemble sur des réseaux complexes.

Double clic sur les symboles de groupe pour descendre à un niveau plus bas.

Utilisez le bouton droite de la souris pour afficher un menu instantané avec des fonctions particulières.

Page 75: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 76

Gestion d’alarmes : Statut d’alarme

Le statut d'alarme est présenté dans sa taille standard une fois ouvert. Il peut être rétréci pour aider à conserver une bonne visibilité de la vue de l’image de fond. La version réduite ne montre pas les noms de sévérité.

N'importe quelle alarme non quittancée d'une sévérité est indiquée par le clignotement du compteur respectif et de son champs coloré.

Filtre : Appelle le dialogue de filtre de statut d'alarme qui contrôle le seuil de sévérité pour le clignotement des compteurs d'alarme aussi bien que les alarmes audibles.

Page 76: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 77

Gestion d’alarmes : Vue support d’équipement

La vue de matériel d’un élément de réseau (NE) fournit une présentation graphique du support d’équipement FOX. C'est le niveau supérieur de la hiérarchie, les niveaux plus bas étant vue d'unité et vue de sous- unité.

L'affichage fournit les détails des unités comprenant leur état d'alarme aussi bien que des informations sur l’élément de réseau NE FOX.

Page 77: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 78

Gestion de configuration : Éléments de réseau

Définition des unités/sous-unités dans l'élément de réseau

Configuration des modules et des interfaces

Interconnexion des ports (brassage)

Ajouter la commutation de protection

Définition des sources d’horloge de l’élément de réseau (synchronisation)

La gestion de configuration du FOXMAN-UN/NV fournit à l'opérateur les fonctions suivantes :

Page 78: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 79

Gestion de configuration : Traitement du cheminement «Trail Handling»

1

Logiciel de gestion de réseau (NP) – On gagne du temps! Le NP épargnera du temps en

contrôlant la configuration bout à bout des cheminements et des circuits.

Permet aux opérateurs de créer semi-automatiquement du cheminement de 2Mb/s, 8Mb/s, VC12 et VC3 entre deux nœuds FOX.

Soutient la création de circuit semi- automatisée de nx64kb/s et 2Mb/s entre deux points finaux dans un réseau FOX.

L’option logiciel de gestion de réseau «Networking Package» fournit une fonctionnalité d’interconnexion bout à bout pour le traitement semi-automatique du cheminement et de circuit et associe les clients aux circuits.

Geneva Basel Zurich

Le logiciel de base fournit la fonctionnalitéde base pour la gestion d’élément.

Page 79: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 80

Circuits protégés

Associe les circuits aux clients

Les circuits configurés manuellement avec le terminal d'exploitation local sont identifiés et importés

Gestion de configuration : Traitement du cheminement

Page 80: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 81

Gestion de configuration : Traitement du cheminement

Le FOXMAN-UN NP fournit l’appui pour PDH (appui total à P0 et P0_nc), SDH et xDSL.

Le FOXMAN-UN NP soutient la modélisation du cheminement, des circuits et des porteurs SNC (Sub Network Connection) aux couches de section, de chemin et de circuit comme définie dans la recommandation G.805 de l'UIT-T.

Le FOXMAN-UN NP soutient également des hiérarchies de transmission ETSI PDH et SDH et des structures de multiplexage.

Le FOXMAN-UN NP fournit différentes méthodes de protection pour le réseau FOX515 et les couches réseau.

Protection de chemin 1+1 bout à bout, e.g. pour TEBIT

Modes de protection SNC et LTP

Protection de section multiplex (MSP)

Caractéristiques principales (1) :

Page 81: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 82

Gestion de configuration : Traitement du cheminement

FOXMAN-UN NP soutient l'identification des configurations complexes comme

Multipoints (Broadcast)

Point-à-multipoints

Conférence de voix

Les opérations suivantes ne font pas partie du NP mais peuvent être effectuées avec le logiciel de base:

Rajout d’un module

Réglage de paramètre à l'intérieur d'un élément de réseau NE

Les ports à trafic sont automatiquement libérés par FOXMAN-UN NP

Caractéristiques principales (2) :

Page 82: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 83

Gestion de configuration : Traitement du cheminement

Rapports qui vous permettent de documenter votre réseau une meilleure planification des activités d'entretien une planification de largeur de bande efficace

Exemples de rapports, qui peuvent être générés utilisant les filtres configurables: Rapport d'une application définie (circuit, cheminement ou

SNCs) Rapport de données de client Tous les circuits inclus dans une section spécifique

comprenant les informations de base du client Circuits/cheminements pour un élément de réseau spécifique Tous les circuits associés à un client spécifique

Les rapports peuvent être envoyés à une imprimante ou un fichier de données peut être généré (en format HTML ou ASCII/CSV)

Caractéristiques principales (3) :

Page 83: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 84

Gestion de performance

Outil de collecte de données de performance pour la surveillance de performance soutenant les intervalles de 15 minutes et/ou de 24 heures

Les données de performance inclues Bit Error, Errored Seconds (ES), Severely Errored Seconds (SES) et plus

Décrit dans les normes G.821, G.826 de l‘UTI-T

Les données de performance rassemblées peuvent être exportées pour l'intégration dans un OSS (système de support d'opération)

Page 84: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 85

Gestion de sécurité

L'utilisateur doit s’authentifier au niveau GUI (Explorateur de réseau & Configurateur) après être connecté au serveur FOXMAN-UN.

Administration simplifiée d'accès d'utilisateur : L'attribution d'un profil et d'un domaine à un utilisateur définit ses permissions d'accès

Le GUI de gestion de sécurité est fourni dans le configurateur NEM

Page 85: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 86

Carte de statut de synchronisation

La carte de synchronisation SDH/PDH permet l'affichage de l'état courant de synchronisation du réseau de transmission numérique pour des liens SDH et PDH

Cela permet une identification rapide et efficace des îles et boucles de synchronisation

Flèches noires montre l'écoulement normal de synchronisation

Flèches rouges indique une boucle d'horloge

Flèches absentes indique une île d’horloge ou de synchronisation

Page 86: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 87

Intégration dans un système de gestion de niveau supérieur

Avec l'interface Northbound SNMP, FOXMAN-UN peut exporter des alarmes et l'information d'inventaire vers un système de gestion de niveau supérieur tel que HP OpenView ou Castlerock SNMPc

Avec la version R8B, une interface Southbound SNMP est disponible, permettant aussi une intégration d'équipement de tiers capable de gérer SNMP

OS: RedHat Linux

FOXMAN-UNSNMP

Northbound IF

OS: Win, HP-UX

HP OpenView

OS: Win

Castlerock SNMPc

Higher Level Management Systems

FOX 515Network Elements

SNMP Southbound IF

3rd Party Equipment with SNMP Agent

Page 87: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 88

Licence de Base et Options

La licence de base inclut Vue graphique du réseau Gestion de section Gestion d'objets étrangers Vue de synchronisation

Les licences optionnelles sont Utilisateurs concourants additionnels Système de repli Logiciel de gestion de réseau Interface Northbound SNMP Gestion de performance

Page 88: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 89

Mercie pour votre

attention!

Page 89: 01 FOX515_Integration_2010-02-08

© ABB Group February 4, 2011 | Slide 90