RX300 Config

download RX300 Config

of 19

Transcript of RX300 Config

  • 8/8/2019 RX300 Config

    1/19

  • 8/8/2019 RX300 Config

    2/19

    System configurator and order-information guidePRIMERGY RX300 Status 2003-10-31

    Instructions

    This document contains basic product and configuration information that will enable you to configure your system viaPC-/System-Architect.

    Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your completePRIMERGY Rack system.

    You can configure your individual PRIMERGY server in order to adjust your specific requirements.

    The System configurator is divided into several chapters that are identical to the current price list and PC-/SystemArchitect.

    Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go throughthe configurator by following the lines from the top to the bottom.

    Section III Memory, example

    There are X memory slots which can be equipped with XXX MB.

    It is permissible to make up to X passes through the memory upgrade options

    S26361-XXX-XXX S26361-XXX-XXX

    Memory XXX MB Memory XXX MB

    X times

    max. X times per system max. X times per system

    In one chapter you can only select as many components (here 4x) as the arrow indicates. 4x

    Please note that there are information symbols which indicate necessary information.

    Further information in the internet see:

    http://www.primergy.com (internet)

    http://extranet.fujitsu-siemens.com/primergy (extranet)

    Prices and availability see price list and PC-/System-ArchitectSubject to change and errors excepted

    Fujitsu Siemens Computers

    SHV Server 2 of 19

    http://www.primergy.com/http://extranet.fujitsu-siemens.com/primergyhttp://extranet.fujitsu-siemens.com/primergyhttp://www.primergy.com/
  • 8/8/2019 RX300 Config

    3/19

    System configurator and order-information guidePRIMERGY RX300 Status 2003-10-31

    Configuration diagram PRIMERGY RX300

    System unit ( I )

    1. PSU 2. PSU Fan 1 - Fan 4 Bay for Local View (frontside)

    Fan 5 - Fan 8 3.5"x 0,5" Floppy disk

    Redundant system-

    Redundant power supply option fans Option

    5,25"x 0,5" IDE-CD / DVD-ROM

    Bank I (2 Modules)

    Xeon DP Accessible drives ( V )

    Bank II (2 Modules)

    Bank III (2 Modules) Needs space for 2

    Xeon DP hard disk drives!

    Memory ( III ) 3.5"x1,6"

    Processor ( II ) Backup drive option

    Hard disk drives ( VI )

    Extension slots channel 1

    SCSI Controller ( VII )Disk Array ( VIII ) 3.5"x1" ID 14Communication/Network ( IX )Miscellaneous ( X )

    3.5"x1" ID 13

    Slot5: PCI 64-Bit / 33MHz, short with Riser, 5V

    RISER option 3.5"x1" ID 12

    Slot4: PCI-X 64-Bit / 133MHz, Low Profile

    channel 2 (optional)

    0-channel-RAID (ZCR)

    Slot3: PCI-X 64-Bit / 100MHz, Low Profile 3.5"x1" ID 2

    HOT PLUG

    Slot2: PCI 64-Bit / 100MHz, Low Profile 3.5"x1" ID 1

    HOT PLUG

    Slot1: PCI 64-Bit / 100MHz, Low Profile 3.5"x1" ID 03Covered,

    ifPC

    I-risercard

    ordered

    2

    0

    3

    P

    CI-Bus

    1

    Fujitsu Siemens Computers

    SHV Server 3 of 19

  • 8/8/2019 RX300 Config

    4/19

    System configurator and order-information guideStart "PRIMERGY RX300" PRIMERGY RX300 Status 2003-10-31

    SW - Configurator

    with OEM-Software without OEM-Software

    for PRIMERGY Server for PRIMERGY Server

    Later use of OEM operating system software is not

    allowed, apart from OEM software by VMware and F5 .

    For all SW products listed below please refer to the corresponding software configurator accessible

    via the Extranet under "PC Configurations, Configurator for PRIMERGY SW", URL see below

    MS - Software: W **) SCO - Software: **) Novell - Software: ***) PRIMECLUSTER *)

    - NT 4.0 Server - SCO UnixWare 7 - NetWare 6 - Clustering

    - NT 4.0 Server Enterprise Edition - NetWare 6.5 (planned) - Load Balancing

    - NT 4.0 Server Terminal Server Edition - NetWare Cluster Services 1.6 and

    - Windows 2000 Server - NetWare Cluster Services 1.7

    - Windows 2000 Advanced Server (planned) with FibreCAT

    - Windows Server 2003, CX200, CX400, CX600

    Web Edition (only English)

    Standard EditionEnterprise Edition Linux - Software: **)

    - SuSE Linux Enterprise Server: S

    - SuSE Professional Linux

    CITRIX-Software for NT: W1 - Red Hat Enterprise Linux

    - Multiuser SW MetaFrame - Red Hat Professional Linux

    LoadBalancing

    Additional User Licences

    MultiPath, Duplex Data

    Manager for NT; W2K; Linux

    FSC System Management *) Pay attention to release information on datasheet under

    Software: V http://www.primecluster.com- RemoteView Software

    - RemoteView Service Board

    - RemoteView Diagnosis **) Pay attention to release and order information in PRINCE -> Operating System

    http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htm

    Backup-Software: U

    - ARCserve for NT ***) Supply over distribution or procurement from FSC VP BC Software

    - ARCserve for NetWare

    You'll find single software configurators and release lists (OS-matrix/system management/security) under following addresses:

    for internal users: http://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htmfor partners: http://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htm

    Continue with PRIMERGY

    HW configurator

    Fujitsu Siemens Computers

    Enterprise Products - PRIMERGY Server 4 of 19

    http://www.primecluster.com/http://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htmhttp://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htmhttp://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htmhttp://vilpart.fujitsu-siemens.de/vil/oec/special/primergy/index_en.htmhttp://vil.mch.fsc.net/vil/oec/special/primergy/index_en.htmhttp://vil.mch.fsc.net/vil/pc/vil/primergy/overview/prince/index_en.htmhttp://www.primecluster.com/
  • 8/8/2019 RX300 Config

    5/19

    System configurator and order-information guideStart PRIMERGY RX300 PRIMERGY RX300 Status 2003-10-31

    Section I Basic unit

    System unit consisting of:

    * 2U Housing including one power supply module

    - hot plug Power supply unit with 1 PSU module and power cord rack 4m lenght

    (can be upgraded with one additional PSU module)

    * hot plug fan unit with 4 system-fans and control logic for 8 fans

    - Additional hot plug system-fan unit with 4 fans as a redundant fans option (option)

    * SCSI Backplane for 1x6 HD

    - Additional upgrade Kit for 2x3 HD (Option)

    * Drives/Bays

    - 6 bays 1" for hot plug SCSI HD

    - 1 bay for 3.5" and 1.6" high backup device, consumes 2 bays 1" for hot plug SCSI HD

    - 2 bays (for accessible drives) with

    - 1 floppy disk 1.44MB 0,5" height

    - 1 IDE-CD-/DVD-ROM 0,5" hight (option)

    - bay for opt. Local View Display on frontside

    * Integrated ServerView Diagnostics Technology for indication of internal failed components

    * Mounting kit for PRIMERGY RX300

    - 1 pair of telescopic rails

    - 2 holders

    - 1 bracket DC-PC-Rack

    - 1 cable management DC-PC-racks

    Mounting kit for mounting of servers in FSC 19" DataCenter- and PRIMECENTER- racks and

    all server racks conforming to EIA standard EIA-310-D for 19" racks.Therefore the mounting kit is variable in deepth from 710-815mm

    Systemboard with:

    * One XEON CPU according to the configurator

    * 5 PCI slots: 2x 64Bit / PCI-X100 low profile (3,3V), hot plug PCI

    with OptiSpeed Bus (-> 133MHz if only one Slot is populated)

    1x 64Bit/PCIX133 low profile (3,3V)

    1x 64Bit/PCIX100 low profile (3,3V) (Slot for 0-channel RAID Controller, ZCR)

    1x 64Bit/33MHz, short full hight (5V)

    - 4 PCI Slots (Standard full hight PCI System - Option)

    1x PCI 64Bit/33MHz short full hight (5 V)

    3x PCI-X 64Bit/100MHz long full hight with PCI Subchassis (risercard option)

    * 6 memory slots for max. 12GB PC2100 DDR RAM. (as soon as 2GB modules are available)

    2-way memory interleave technology => 3 banks with 2 slots each, max. 2GB modul per slot

    Additional Chipkill and Hot Spare Memory support for memory modules

    * 0-channel RAID support for one 100MHz PCI-X slot (ZCR)

    * Fast-IDE (ATA) controller on-board (for 2x2 drives)* 2-channel Ultra 320 SCSI controller (Adaptec 7902) on-board

    * 2* Gbit Ethernet LAN on-board (in chipset: BroadCom 5704 compatible)

    * Graphics controller ATI Rage XL (8 MB RAM) on-board

    * BMC ( Baseboard Management Controller ) Servermanagement Chip on-board

    External Interfaces:

    * 1x optional Centronics (parallel, 25 pin, EPP/ECP compatible)

    * 1x keyboard (PS/2)

    * 1x mouse (PS/2)

    * 1x VGA (15 pin)

    * 3x USB 1.1 (OHCI) with 12MBit/s (2x external at the rear, 1x at the frontside, no USB wakeup)

    * 2x LAN RJ45

    Cables:

    1. IDE cable for CD/DVD.

    2. Wide LVD SCSI cable for connection of the HD backplane.

    3. Power cable

    Software:

    - ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView

    Cables included in basic unit

    Connections Cable PRIMERGY RX300

    1. IDE CD/DVD

    2. Backplane for 1x6SCSI hard disks incl. terminator Key:

    68pins3. Power cable 68 or 50pins

    IDE

    terminator

    A

    Fujitsu Siemens Computers

    SHV Server 5 of 19

  • 8/8/2019 RX300 Config

    6/19

    System configurator and order-information guideA PRIMERGY RX300 Status 2003-10-31

    Rack version for 19'' racks with

    1 hot plug power supply module

    Basic unit with

    - 1x XEON DP (512kB SLC) processor

    with 533MHz Frontside Bus (max. 2)

    512MB DDR RAM PC2100 encluded

    2,4GHz / 512kB S26361-K888-V1012,66GHz / 512kB S26361-K888-V102

    2,8GHz / 512kB S26361-K888-V103

    3,06GHz / 512kB S26361-K888-V104

    3,06GHz / 1M S26361-K888-V134

    1GB DDR RAM PC2100 encluded

    2,4GHz / 512kB S26361-K888-V111

    2,66GHz / 512kB S26361-K888-V112

    2,8GHz / 512kB S26361-K888-V113

    3,06GHz / 512kB S26361-K888-V114

    3,06GHz / 1M S26361-K888-V144

    2GB DDR RAM PC2100 encluded

    2,4GHz / 512kB S26361-K888-V121

    2,66GHz / 512kB S26361-K888-V122

    2,8GHz / 512kB S26361-K888-V123

    3,06GHz / 512kB S26361-K888-V1243,06GHz / 1M S26361-K888-V154

    S26113-F600-E6

    2nd power supply module (PSU)

    for redundancy (500W) For later conversion the following kit is available:

    incl. power cord for rack 1.) 1 power supply module 500W hot plug S26113-F600-L6

    4m lenght incl. power cord for rack 4 m lenght

    max. 1x per system

    S26361-F2621-E3Redundant Fans option

    4 system hot plug fans in cage

    max. 1x per system

    B

    Fujitsu Siemens Computers

    SHV Server 6 of 19

  • 8/8/2019 RX300 Config

    7/19

    System configurator and order-information guideB PRIMERGY RX300 Status 2003-10-31

    PRIMERGY 19" Rack

    PRIMERGY PRIMECENTER-Rack

    "Rack-mounting ex factory"

    SNP:SY-F1647E301-P This service is to be ordered once

    Installation ex works for one per installable server/storage

    server or subsystem. subsystem, in order to get the

    Hereby the rack will be delivered server/storage subsystem

    completely pre-mounted and mounted into the PRIMERGY racks.

    all wired connections are tested In case of the 46 U PRIMERGY rack,

    With racks 12U, 24U, 38U: this service has to be ordered,

    Systems and components to get the mounting kits and the

    will be delivered installed in the rack cables installed.

    With racks 46U:

    Systems and components

    will be delivered separately

    To be ordered only together with

    a PRIMERGY-

    PRIMECENTER rack

    e.g.: Important notice !

    S26361-K826-V10x The mounting kit for PRIMERGY RX300

    refer configurator PC-rack is included the basic version and

    max. 1x per system will be delivered with every RX300

    S26361-F1331-L93

    Additional mounting kit for PRIMERGY42/23U Classic racks

    containing 1 pair of spacer needed to adapt mounting kit

    coming with RX300 for use in PRIMERGY Classic racks.

    Fully fitting with RX300 is not allowed, free U needed to arange

    cables.

    C

    Fujitsu Siemens Computers

    SHV Server 7 of 19

  • 8/8/2019 RX300 Config

    8/19

    System configurator and order-information guideC PRIMERGY RX300 Status 2003-10-31

    Section II Processor

    There are 2 processor FCPGA slots available.

    It is also possible to upgrade a dual-processor system later on.

    Two processors with different clock frequencies are not possible

    A multi-processor operating system is required for a dual-processor system.

    S26361-F2827-E240 S26361-F2827-E260 S26361-F2827-E280

    XEON 2.4GHz/533MHz FSB XEON 2.66GHz/533MHz FSB XEON 2,8GHz/533MHz FSB

    with 512kB SLC on Chip, with 512kB SLC on Chip, with 512kB SLC on Chip,

    heat sink heat sink heat sink

    occupies slot for one CPU occupies slot for one CPU occupies slot for one CPU

    max. 1x per system max. 1x per system max. 1x per system

    S26361-F2827-E300 S26361-F3016-E300

    XEON 3,06GHz / 533MHz FSB XEON 3,06GHz/533MHz FSB

    with 512kB SLC on Chip, with 1M TLC on Chip

    heat sink (TLC = Third Level Cache)

    heat sink

    occupies slot for one CPU occupies slot for one CPU

    max. 1x per system max. 1x per system

    Section III Memory

    There are 6 memory slots available (3 banks, each bank consists of two slots => 2 modules per bank are necessary)

    They can optionally be equipped with 256 MB, 512 MB, 1GB or 2GB registered PC2100 DDR modules

    One bank optionally can be configured as hot spare bank.

    In each basic unit the first memory bank is already equipped with either 512MB or 2GB memory,

    so the memory extensions can still be configured up to two times for the second and third memory bank.Maximum configurable memory extension is 10GB.

    (this is possible with a 2GB basic unit + 2 x 4GB memory extensions ! )

    The maximum extension of 12GB is possible through the order of a 512MB basic unit with 2 x 4GB memory

    extensions and another order of a lose 4GB extension !

    No mix of modules within one memory bank allowed.

    S26361-F2762-E523 S26361-F2762-E524 S26361-F2762-E525 S26361-F2762-E526

    Main memory 512MB Main memory 1GB Main memory 2GB Main memory 4GB

    PC2100 registered DDR RAM PC2100 registered DDR RAM PC2100 registered DDR RAM PC2100 registered DDR RAM

    2x with chipkill support with chipkill support with chipkill support with chipkill support

    consisting of 2 modules consisting of 2 modules consisting of 2 modules consisting of 2 modules

    occupies one bank occupies one bank occupies one bank occupies one bank

    max. 2x per system max. 2x per system max. 2x per system max. 2x per system

    For the upgrade of servers with Memory 4GB S26361-F2762-L526,

    which were delivered before September 2003,

    the Upgrade kit "air hood memory" (S26361-F3020-L10) is necessary.

    Section IV Graphics

    Graphics Controller ATI 8MB is included in the basic unit.

    Other graphic cards only possible on PCI bus

    by Customizing.

    D

    Fujitsu Siemens Computers

    SHV Server 8 of 19

  • 8/8/2019 RX300 Config

    9/19

    System configurator and order-information guideD PRIMERGY RX300 Status 2003-10-31

    Section V Accessible drives

    SNP:SY-F2313E1-P SNP:SY-F2312E1-P

    CD-ROM 0,5" 24xATAPI DVD drive 0,5"

    Connector: LD50 8/24x or faster

    incl. description (Ger/US) anthracite bezel

    0.5" * 5.25", anthracite bezel occupies one drive bay

    max. 1x per system max. 1x per system

    S26361-F2233-E6 An option "hot plug backup drive", occupying

    Tape drive DAT DDS4 hot plug 2 x 1" hard disk bays can be configured .

    20GB, 2.8MB/s, U2W SCSI The hot plug backup drive requires a

    1.6 x 3.5", anthracite bezel Zero-channel RAID controller

    within a hot replace cage or a 1- or 2- channel U320 RAID controller

    SCA connector (80-pins) (Adaptec or LSI).

    occupies 2 x 1" hard disk bays

    RAID controller necessary

    max. 1x per system

    Section VI Hard disks drives

    The 80-pin SCA hard disks are plugged in a 1- or 2-channel backplane which is connected to the on-board SCSI

    controller with a 68pin cable, if no other PCI-controllers are ordered.

    If the option "hot plug backup drive" is configured only 4 bays for hard disks are available

    hot replace is only possible with DAC and RAID setup.

    S26361-F2764-E136 S26361-F2764-E173 S26361-F2764-E114

    Hard disk 36GB Hard disk 73GB Hard disk 146GB

    10000rpm,

  • 8/8/2019 RX300 Config

    10/19

    System configurator and order-information guideE PRIMERGY RX300 Status 2003-10-31

    Section VII SCSI-/ Fibre-Channel Controller

    on-board SCSI-controller for accessible drives and SCSI-HDs

    The system is equipped with a two channel Utra 320 SCSI on board controller and embedded "HostRAID".

    HostRAID offers the RAID levels 0, 1, 10 (striping and mirroring) witout any additional costs.

    Per SCSI channel max. 2 RAID1 arrays with each two disks and one hot spare drive can be configured.

    Administration of Host RAID will be done with the Adaptec Storage Manager Browser Edition.HostRAID supports Windows 2000. Windows 2003 and LINUX are planned.

    The simultaneous operation of the "Host RAID" function and the DDS4 (no hot Plug DDS4) at onboard SCSI

    controller is only under W2K with the host RAID driver v.: 1.01a (or higher) possible.

    1-channel standard SCSI-cabling of a basic unit PRIMERGY RX300 with on-board controller

    1. One channel of the Ultra 320 SCSI controller is connected to the 6 internal hard disks, if no additional HD controllers are

    (Two backplanes with 3 HDs each cascaded to one SCSI channel with 6HD`s = standard cabling).

    configured for internal HDs.

    2. The second channel of the Ultra 320 SCSI controller is available for internal accessible SCSI drives.

    2-channel SCSI cabling of a PRIMERGY RX300 basic unit with on-board controller and "Conversion kit 6 HD 2-channel"

    For the order of a "Conversion kit 6 HD 2-channel (S26361-F2612-E3)",

    both channels of the Ultra 320 SCSI controller are connected to one backplane for 3 HDs each.

    All internal cables and adapters for the basic unit and for components are included.

    1x per RX300

    T26139-Y3882-E101 If the internal HD are connected to a configurable controller (e.g. Disk Array),External on-board SCSI Interface the channel of the on-board controller can also be used externally.

    Cable and external

    connector interface (UHD) Only SX30 Backup is released for the external connection

    max. 1x per system for ext. of the on-board SCSI controller

    More then 1x PCI standard slot short usage Only 1x PCI standard slot short usage Only 1x PCI standard slot short usage,

    other PCI cards are low profile usage

    Standard PCI System with (encluded in basic unit)

    PCI-risercard option incl. PCI-cage Low Profile System

    (for 3 PCI-standard cards, long) 2x 64Bit / PCIX100 low profile (3,3V), hot plug PCI

    3 Slots PCI-X 100MHz / 64 bit, long 1x 64Bit / PCIX133 low profile (3,3V)

    1x 64Bit / PCIX100 low profile (3,3V), with EMRL

    P

    SCSI- and Fibre Channel controller for external drives and peripheral devices

    while stocks last

    S26361-F2843-E1 S26361-F2624-E1 S26361-F2399-E1

    2GBit/s FC controller 2GBit/s FC controller SCSI 160 controller

    Emulex Emulex Adaptec SCSI Card 29160

    LP9802 LP9002L 1 channel: LVD + Fast/ Ultra (decoupl.)

    1 Cannel 2GBit/sec FC controller 1 Channel 2GBit/sec FC controller LVD connect. for HD, without cable

    3x LC Interface for 50um Fiber LC Interface for 50um Fibre Fast/Ultra connect. for acc. drivesPCI 64Bit / 133MHz, 170mm PCI 64Bit / 66MHz, 170mm 64/66 PCI, min 180 mm

    3.3V and 5V tolerant signaling 3.3V and 5V tolerant signal ing int: Fast 50 pol oder Ul tra HD68

    max. 3x per system max. 3x per system + LVD HD68; ext: HD68(LVD)

    SW:

    max. 2x per system

    All controllers for the connection of external storage system are delivered without cables. Attention

    For the configuration of external cabling see the configurator for external storage system. 2GBit/s FC control ler

    require other interface

    3x, to be There are other components such as switches, GBICs or cables which can be ordered for connectors for the

    continued fibre channel SAN attachments (see price list) optical cables than

    on next page 1GBit/s fibre channel

    F

    S26361-F2622-E2

    Fujitsu Siemens Computers

    SHV Server 10 of 19

  • 8/8/2019 RX300 Config

    11/19

    System configurator and order-information guideF PRIMERGY RX300 Status 2003-10-31

    Section VIII Disk Array

    3x, to be The fitting connection cables can be found in the The cables for the connection of the

    continued configurator "external storage systems." RAID controller to HD backplanes in the

    on previous system are included within the basic unit.

    page Adaptec or Mylex / LSI controllers

    1-channel U160 ( Mylex ) SCSI controller for Disk Array

    Mixing Adaptec and Mylex / LSI controllers

    is not supported S26361-F2406-E16

    1-channel RAID controller U160

    Mylex / LSI

    AcceleRAID 160 (Bobcat)

    16MB EDO Cache

    without BBU

    The cables for the connection from the connector: intern. HD68;

    subsystems (SX30) to the RAID control lers extern: VHDCI

    see configurator SX30. without cable

    No SX30-release for 1-channel controllers! incl. SW and description (G/US)

    32/33 PCI controller

    3.3V and 5V tolerant signaling

    max. 2x per system

    1-channel U320 SCSI Controller for Disk Array

    S26361-F3005-E64

    1-channel RAID Controller U320

    LSI

    320-1

    64MB SDRAM ECC Cache

    BBU optional

    plug: internal 1x HD68;

    external: 1x VHDCI

    without cable

    incl. SW and description (Ger/US)

    64/66 PCI controller, 180mm

    3.3V and 5V tolerant signaling

    max. 2x per system

    S26361-F3005-E10

    Cache Battery Backup Unit

    max. 1x per controller

    2-channel U160 ( Mylex ) SCSI controller for Disk Array

    S26361-F2569-E64

    2-channel RAID Controller U160

    Mylex / LSIAcceleRAID 352 (Leopard)

    64MB SDRAM ECC Cache

    The cables for the connection from the BBU optional

    subsystems (SX30) to the RAID controllers Connector: internal 2x HD68;

    see configurator SX30. external: 2x VHDCI

    No S30-release for 1-channel controllers! without cable

    incl. SW and description (Ger/US)

    64/33 PCI Controller, 330mm

    3.3V and 5V tolerant signaling

    max. 2x per system

    S26361-F2569-E10

    RAID Ctrl, Battery Backup Unit

    3x, to be max. 1x per controller

    continuedon next page

    G 1 G 2

    Fujitsu Siemens Computers

    SHV Server 11 of 19

  • 8/8/2019 RX300 Config

    12/19

    System configurator and order-information guide

    PRIMERGY RX300 Status 2003-10-31

    G 1 G 2

    3x, to be 2-channel Ultra 160 (Adaptec / U320 (LSI) SCSI controller for Disk Array

    continued

    on previous S26361-F2385-E32

    page 2-channel RAID Controller U160

    Adaptec

    3200 S

    32MB SDRAM ECC Cache

    BBU optional

    connector: internal 2x HD68;

    external: 2x VHDCI

    without cable

    2x incl. SW and description (Ger/US)

    64/33 PCI Controller, 330mm

    3.3V and 5V tolerant signaling

    max. 2x per system

    S26361-F2386-E32

    RAID Ctrl, Cache Upgrade 32MB

    32 MB SDRAM ECC Cache

    max. 1x per Controller

    S26361-F2386-E10

    RAID Ctrl, Battery Backup Unit

    max. 1x per Controller

    4-channel Ultra 160 SCSI controller for Disk Array

    S26361-F2190-E128

    4-channel RAID controller U160

    Mylex / IBM

    eXtremeRAID 2000 (Big Apple)

    128MB SDRAM ECC Cache

    BBU

    connector: internal: 2x HD 68;

    external: 4x VHDCI

    incl. SW and description (G/USA)

    64/33 PCI controller, 330 mm

    3.3V and 5V tolerant signaling

    max. 2x per system

    H

    Fujitsu Siemens Computers

    SHV Server 12 of 19

  • 8/8/2019 RX300 Config

    13/19

    System configurator and order-information guideP PRIMERGY RX300 Status 2003-10-31

    SCSI-/ Fibre-Channel Controller Low Profile

    SCSI controller for external SCSI-HDs

    S26361-F2737-E201

    SCSI 160 controller, lp

    Adaptec SCSI Card 29160LP

    1 channel U160 LVDonly external connection

    64/66(32/33) PCI Low Profile

    ext: VHDCI, 68 pol., U160

    SW:

    max. 2x per system

    Fibre Channel Controller for subsystems and SAN

    while stocks last

    S26361-F2624-E201 S26361-F2843-E201

    2GBit/s FC controller 2GBit/s FC Controller

    Emulex Emulex

    LP9002L, PCI Low Profile LP9802, PCI Low Profile LP9802 only for Novell Netware.

    1 Channel 2GBit/sec FC control ler 1 Channel 2GBit/sec FC controller Microsoft and Linux Support

    LC Interface for 50um Fibre LC Interface for 50um Fibre are in process.

    PCI 64Bit/66MHz, 170mm PCI 64Bit / 133MHz, 170mm3.3V and 5V tolerant signaling 3.3V and 5V tolerant signaling

    max. 3x per system max. 3x per system

    Attention There are other components

    2GBit/s FC controller require such as switches, GBICs

    other interface connectors or cables which can be

    for the optical cables than ordered for fibre channel SAN

    1GBit/s fibre channel. attachments (see price list)

    All controllers for the connection of external storage system are delivered without cables.

    4x, to be For the configuration of external cabling see the configurator for external storage system.

    continued

    on next page

    L

    Fujitsu Siemens Computers

    SHV Server 13 of 19

  • 8/8/2019 RX300 Config

    14/19

    System configurator and order-information guideL PRIMERGY RX300 Status 2003-10-31

    Disk Array Low Profile

    Mixing Adaptec and Mylex / LSI controllers

    Adaptec or Mylex / LSI controllers is not supported

    4x, to be zero-channel U320 RAID controller for Disk Array

    continued

    on previous S26361-F2728-E248

    page 0-channel RAID controllerAdaptec zero-channel RAID controller

    2010S PCI Low Profile Adaptec 2010S is always to be

    48MB SDRAM ECC Cache installed in slot 3 and is only available

    for low profile configuration.

    in combination with on-board

    U320 SCSI controller

    without cable

    incl. SW and description (Ger/US)

    64/66 PCI controller The cable for the connection of the

    3.3V signaling RAID controller to HD backplane in the

    max. 1x per system system is included within the basic unit.

    1-channel U320 ( Adaptec ) / U160 ( Mylex ) SCSI Controller for Disk Array

    S26361-F2751-E264 S26361-F2406-E2161-channel RAID Controller U320 1-channel RAID Controller U160

    Adaptec Mylex / LSI

    2120S PCI Low Profile The cables for the connection from the BobcatPCI Low Profile

    64MB SDRAM ECC Cache subsystems (SX30) to the RAID Controllers 16MB EDO Cache

    BBU optional see configurator SX30. without BBU

    plug: internal 1x HD68; connector: intern. HD68;

    external: 1x VHDCI extern: VHDCI

    without cable without cable

    incl. SW and description (Ger/US) incl. SW and description (G/US)

    64/66 PCI controller, 180mm lp 1-channel RAID controller Adaptec 2120S 32/33 PCI Controller 180 mm

    3.3V and 5V tolerant signaling may only be installed into slot 1 or 2 . max. 2x per system

    max. 2x per system

    1-channel U320 (LSI) SCSI controller for Disk Array

    S26361-F2752-E10

    Cache Battery Backup Unit S26361-F3005-E264max. 1x per controller 1-channel RAID Controller U320

    LSI

    320-1 Low Profile

    64MB SDRAM ECC Cache

    BBU optional

    2x plug: internal 1x HD68;

    external: 1x VHDCI

    without cable

    incl. SW and description (Ger/US)

    64/66 PCI Controller, 180mm lp

    3.3V and 5V tolerant signaling

    max. 2x per system

    2-channel Ultra 320 ( Adaptec ) SCSI controller for Disk Array

    S26361-F2752-E228 S26361-F3005-E10

    2-channel RAID Controller U320 Cache Battery Backup Unit

    Adaptec max. 1x per controller

    2200S PCI Low Profile

    128MB SDRAM ECC Cache

    BBU optional

    plug: internal 2x HD68; 2-channel RAID controller Adaptec 2120S

    external: 2x VHDCI may only be installed into slot 1 or 2 .

    without cable

    incl. SW and description (Ger/US)

    64/66 PCI controller, 180mm lp

    3.3V and 5V tolerant signaling

    max. 2x per system

    S26361-F2752-E10

    Cache Battery Backup Unit

    max. 1x per controller

    M Fujitsu Siemens Computers

    SHV Server 14 of 19

  • 8/8/2019 RX300 Config

    15/19

    System configurator and order-information guideH PRIMERGY RX300 Status 2003-10-31

    Section IX Communication / Network

    On-board LAN Controller

    Gigabit Ethernet Controller on-board Teaming: Failover, Load Balancing

    2x 1GBit BMC5704 compatible The Intel LAN Controllers 10/100TX. 1000SX , 1000TX

    Server Adapter, BroadCom can be used with the on-board controller in Teaming Mode

    ext: for RJ 45-connector betrieben werden. Restriction with -F2839.SW: AFT, VLAN, Fast Channel With Broadcom on-board adapters for Gigabit Ethernet must be used

    for the teaming the Broadcom driver.

    Two onboard LAN ports can likewise educate a team.

    A) Adapters with Teaming capability 10-1000TX /SX

    S26361-F2643-E1

    Fast Ethernet Contr. 10/100TX

    Intel Pro 100 Server Adapter

    AFT under NT und NW also

    with on-board LAN, WOL, load bal.

    32/33 PCI, min. 120 mm, hp

    ext: for RJ45-plug Note: Intel Pro/1000 MT

    SW: VLAN, Fast Etherchannel Adapter may not be

    max. 3x per system installed into slot 5.

    S26361-F2732-E1 S26361-F2730-E1 S26361-F2839-E1

    Gigabit Ethernet Contr. 1000SX Gigabit Ethernet Contr. 1000TX Gigabit Ethernet Contr. 1000TX

    Intel Pro/1000 XF Server Adapter Intel Pro/1000 XT Server Adapter Intel Pro/1000 MT Adapter

    Adapter Teaming Support Adapter Teaming Support PCI 32 (33/66MHz), min 122 mm

    3x PCI-X (PCI64/66), min 163 mm PCI-X (PCI64/66), min 163 mm ext: for RJ45-plug, Cat 5

    ext: for Duplex SC-connector ext: for RJ45-connector, Cat 5 connection with Cat 5 cabling

    connection with Cat 5 cabling SW: VLAN, Fast Etherchannel

    SW: VLAN, Fast Etherchannel SW: VLAN, Fast Etherchannel max. 3x per system

    max. 3x per system max. 3x per system

    B) Dual Port Adapter 100TX IPsec with 3DES (156 bit key) has export

    restriction for several countries.

    S26361-F2606-E1 No restriction to countries of the EU and:

    Fast Ethernet dual 10/100TX IPsec - Australia,Intel Pro 100S Dual Port Server - Japan,

    Adapter, with IPsec 3DES - Canada,

    AFT under NT, W2k, NW also - New Zealand,

    with on-board LAN, WOL, load bal. - Norway,

    64/66 bit PCI, min 120 mm, hp - Poland,

    ext: for 2 x RJ45-connector - Switzerland,

    SW: VLAN, Fast Etherchannel - Czechoslovakia,

    max. 2x per system - Hungary

    - United States

    I

    Fujitsu Siemens Computers

    SHV Server 15 of 19

  • 8/8/2019 RX300 Config

    16/19

    System configurator and order-information guideI PRIMERGY RX300 Status 2003-10-31

    C) Token Ring

    while stocks last

    S26361-F2117-E502

    Token Ring Controller

    Smart Ringnode MK4

    100/16/4 Mbit, Madge

    AFT (NT4, W2K) with 2 contr.,

    2 redundant rings with 4 contr.

    32/33 PCI, min. 164 mm

    ext: for RJ45 or SUB-D9-plug

    SW:

    max. 2x per system

    S26361-F1809-E1

    ISDN S0 Controller PCI

    Eicon Diva Server BRI-2M

    Inkl. S0-connector

    occupies short PCI slot

    S0-Interface

    max. 2x per system

    S26361-F2571-E8

    Parallel Port Option

    Centronics

    Cable with 25-pin plug

    for a Centronics Parallel Port

    Interface

    max. 1x per system

    J

    Fujitsu Siemens Computers

    SHV Server 16 of 19

  • 8/8/2019 RX300 Config

    17/19

  • 8/8/2019 RX300 Config

    18/19

    System configurator and order-information guideJ / N PRIMERGY RX300 Status 2003-10-31

    Section X System Management Products (RemoteView)

    S26361-F1790-E219

    RemoteView Software V3.10

    remote maintenance software, manual

    S26361-F2425-E100

    RemoteView Service Board

    occupies 1* PCI slot

    max. 1x pro System

    S26361-F2425-E121 RemoteView external Power Supply

    RemoteView Cables S26361-F2425-L300

    Manual inclusive power cable G and power cable rack

    S26361-F2116-E14

    RemoteView Diagnosis

    IDE Chipdisk

    at the on-board IDE-Controller

    occupies 1* IDE slot

    max. 1x pro System

    S26361-F2557-E102

    LocalView Option Kit The LocalView Display is only released for

    - LCD Display with mountingkit Microsoft operating systems and

    - 2 x 20 char. ServerView Agents from version 2.57.06 on !"

    max. 1x per system

    Section

    XIMiscellaneous

    S26361-F1652-L4 In connection with rack configurations

    Modem external 56kbps (V.90) the install variant of the modem

    MultiTech (S26361-F1652-E4) has to be ordered

    MT5643ZBA-Global (see rack configurator)

    international approval

    incl. 2m Telephon cord RJ11/RJ11

    Adapter Plug RJ11/TAE

    Serial Interface cable DB25m / DB9f

    AC-Adapter w. German Power Cord

    occupies one COM port

    max. 1x per system

    Section XII Country specific power cord

    Options and other peripherals

    For other options, refer to separate "Product specific options"

    These options are supplied lose with the shipment

    For suitable peripherals for this product, please refer to the section "Peripherals/communication"

    Country specific power cords are not required for rack versions, except for USA&Canada.

    Power cords are shipped in a rack version with inlet connector for non-heating apparatus.

    Description in englisch. Both included in basic unit.

    (1x with Standard PSU, 2x with hot plug upgrade)

    T26139-Y1742-E10 USA, Canada

    For shipments to USA&Canada, you have to order

    one power cord (1,8m, grey) per power supply.

    End PRIMERGY RX300

    Fujitsu Siemens Computers

    SHV Server 18 of 19

  • 8/8/2019 RX300 Config

    19/19

    System configurator and order-information guide

    PRIMERGY RX300 Status 2003-10-31

    Change Report

    Date Order number Changes

    2003-10-31 SNP:SY-F2244E2-A 1GBit/s FC controller Qlogic QLA 2200F - no longer available

    2003-10-31 SNP:SY-F2244E1-A 1GBit/s FC controller Qlogic QLA 2200 - no longer available

    2003-10-21 S26361-F3006-E127 Main memory 4GB PC2100 registered DDR RAM - now available2003-10-20 S26361-F3006-E128 2-channel RAID controller U320 LSI - not available

    26.09.2003 S26361-F2843-E201 2GBit/s FC Controller Emulex LP9802 Low Profile - now max. 3x per system possible

    26.09.2003 S26361-F2624-E201 2GBit/s FC Controller Emulex LP9002 Low Profile - now max. 3x per system possible

    26.09.2003 S26361-F2843-E1 2GBit/s FC Controller Emulex LP9802 - now max. 3x per system possible

    26.09.2003 S26361-F2624-E1 2GBit/s FC Controller Emulex LP9002 - now max. 3x per system possible

    2003-09-18 S26361-F2839-E201 Gigabit Ethernet Contr. 1000TX lp - now available

    2003-09-18 S26361-F2839-E1 Gigabit Ethernet Contr. 1000TX - now available

    2003-08-13 S26361-F3005-E264 1-channel RAID controller U320 LSI lp - now available

    2003-08-13 S26361-F3006-E128 2-channel RAID controller U320 LSI - now available

    2003-08-13 S26361-F3005-E10 Cache Battery Backup Unit - now available

    2003-08-13 S26361-F3005-E64 1-channel RAID controller U320 LSI - now available

    2003-08-07 S26361-F2752-E228 2-channel RAID controller U320 Adaptec 2200S lp - now available

    2003-08-07 S26361-F2751-E264 1-channel RAID controller U320 Adaptec 2120S lp - now available

    2003-08-07 S26361-F2752-E128 2-channel RAID controller U320 Adaptec 2200S - will not be available

    2003-08-07 S26361-F2751-E64 1-channel RAID controller U320 Adaptec 2120S - will not be available

    2003-08-07 S26361-F3016-E300 XEON DP processor 3,06GHz 1M/533FSB - now available2003-08-07 S26361-K888-V154 Rack-version PY RX300f X/3.06/1M 2G - now available

    2003-08-07 S26361-K888-V144 Rack-version PY RX300r X/3.06/1M 1G - now available

    2003-08-07 S26361-K888-V134 Rack-version PY RX300f X/3.06/1M 512M - now available

    2003-06-24 S26361-F2843-E201 2GBit/s FC Controller Emulex LP9802 PCI Low Profile - now available

    2003-06-24 S26361-F2843-E1 2GBit/s FC Controller Emulex LP9802 - now available

    2003-05-15 S26361-F2752-E228 2-channel RAID controller U320 Adaptec 2200S lp - as soon as available

    2003-05-15 S26361-F2751-E264 1-channel RAID controller U320 Adaptec 2120S lp - as soon as available

    2003-05-15 S26361-F2406-E216 1-channel RAID controller U160 Mylex / LSI Bobcat lp - now available

    2003-05-15 S26361-F2816-E228 0-channel RAID controller Adaptec 2020 S lp - will not be available

    2003-05-15 S26361-F2752-E10 Cache Battery Backup Unit - now available

    2003-05-15 S26361-F2752-E128 2-channel RAID controller U320 Adaptec 2200S - as soon as available

    2003-05-15 S26361-F2751-E64 1-channel RAID controller U320 Adaptec 2120S - as soon as available

    2003-04-25 S26361-K881-V114 Rack-version with 1GB PC2100 DDR RAM 3.06GHz / 512kB - now available

    2003-04-25 S26361-K881-V113 Rack-version with 1GB PC2100 DDR RAM 2.8GHz / 512kB - now available

    2003-04-25 S26361-K881-V112 Rack-version with 1GB PC2100 DDR RAM 2.66GHz / 512kB - now available2003-04-25 S26361-K881-V111 Rack-version with 1GB PC2100 DDR RAM 2.4GHz / 512kB - now available

    2002-10-18 First draft

    Fujitsu Siemens Computers

    SHV Server 19 of 19