Corinex 11+1 Phase Coupler - G-NetTic 11+1 Coupler... 1 Corinex Communications 1000-1090 West Pender...

1
www.corinex.com 1 Corinex Communications 1000-1090 West Pender Street Vancouver, BC Canada V6E 2N7 Tel: 604.692.0520 Fax: 604.694.0061 E-mail: [email protected] Corinex Communications a.s. Nove Zahrady I. 13/A 821 05 Bratislava 2 Slovak Republic, Europe E-mail: [email protected] Corinex Communications Corp. 808A, ZhenYe Int. Business Centre 3101-90 QianHai Road, NanShan District, ShenZhen, GuangDong, 518052, China E-mail: [email protected] Corinex 11+1 Phase Coupler Introduction The Corinex 11+1 phase coupler is a passive electronic device that connects multiple electrical circuits in the 2-34 MHz frequency band. The product is used to inject Powerline signals into upwards of 11 electrical connections, from one Powerline master device. All circuits t h e n become one common Powerline network for data, VoIP, or IP Video conferencing. The Corinex 11+1 phase coupler is typically used in Multi-Dwelling Units that have multiple electric meters connected to individual premises; each of the outputs on the device is connected to the load side of the meter, effectively bypassing the meter and thus avoiding signal attenuation issues from trying to channel the Powerline signal through the meter. The coupler can also be installed at substations for AMI/BPL deployments to connect to multiple feeders/lines. The phase coupler has a coaxial input for compatibility with the Corinex CableLAN adapter. The Customer Premise Equipment (CPE) in each of the individual premises would be the Corinex AV200 Powerline adapters in either desktop or Wall Mount versions. The bandwidth from the coaxial port (connected to the master or Head-End) is shared between each of the CPE devices in the individual premises. Standard installation of the 11+1 p h a s e coupler fi r s t requires the connection of the supplied power cord o n o n e e n d to the electrical circuit on the load side of the meter (one clamp goes to phase, the other clamp to neutral line), followed by insertion of the o p p o s i t e power cord end to one of the outlets on the coupler. The same procedure can be repeated for remaining phases/line segments, for a maximum total of 11 connected segments. Technical Specifications 2013.02 Ver.3 Capacitive coupling Coupling method Interfaces Unit dimensions 126 mm × 85 mm × 63 mm Electrical parameters 11 × AC connector 1 × F connector Input voltage: AC up to 230 V Line frequency: 50/60 Hz (EU/US) Operating temperature : 0 °C to 50 °C (32 °F to 122 °F) Environmental parameters Product code CXZ-CXP-PH12 Product features and design may vary by version and region. Package Contents Corinex 11+1 Phase Coupler × 1 Power cord with 2 terminal clamps × 11 power outlet on coupler coax connector L1 L2 L3 N 11+1 coupler

Transcript of Corinex 11+1 Phase Coupler - G-NetTic 11+1 Coupler... 1 Corinex Communications 1000-1090 West Pender...

Page 1: Corinex 11+1 Phase Coupler - G-NetTic 11+1 Coupler... 1 Corinex Communications 1000-1090 West Pender Street Vancouver, BC Canada V6E 2N7 Tel: 604.692.0520 Fax: 604.694.0061 E-mail:

www.corinex.com 1

Corinex Communications 1000-1090 West Pender StreetVancouver, BCCanada V6E 2N7Tel: 604.692.0520 Fax: 604.694.0061 E-mail: [email protected]

Corinex Communications a.s. Nove Zahrady I. 13/A821 05 Bratislava 2Slovak Republic, EuropeE-mail: [email protected]

Corinex Communications Corp. 808A, ZhenYe Int. Business Centre3101-90 QianHai Road, NanShan District, ShenZhen, GuangDong, 518052, China E-mail: [email protected]

Corinex 11+1 Phase Coupler

Introduction

The Corinex 11+1 phase coupler is a passive electronic device that connects multiple electrical circuits in the 2-34 MHz frequency band. The product is used to inject Powerline signals into upwards of 11 electrical connections, from one Powerline master device. All circuits t h e n become one common Powerline network for data, VoIP, or IP Video conferencing. The Corinex 11+1 phase coupler is typically used in Multi-Dwelling Units that have multiple electric meters connected to individual premises; each of the outputs on the device is connected to the load side of the meter, effectively bypassing the meter and thus avoiding signal attenuation issues from trying to channel the Powerline signal through the meter. The coupler can also be installed at substations for AMI/BPL deployments to connect to multiple feeders/lines. The phase coupler has a coaxial input for compatibility with the Corinex CableLAN adapter. The Customer Premise Equipment (CPE) in each of the individual premises would be the Corinex AV200 Powerline adapters in either desktop or Wall Mount versions. The bandwidth from the coaxial port (connected to the master or Head-End) is shared between each of the CPE devices in the individual premises.

Standard installation of the 11+1 p h a s e coupler � r s t

requires the connection of the supplied power cord o n

o n e e n d to the electrical circuit on the load side of the

meter (one clamp goes to phase, the other clamp to

neutral line), followed by insertion of the oppos i te power

cord end to one of the outlets on the coupler. The same

procedure can be repeated for remaining phases/line

segments, for a maximum total of 11 connected segments.

Technical Speci�cations

2013.02 Ver.3

Capacitive couplingCoupling method

Interfaces

Unit dimensions 126 mm × 85 mm × 63 mm

Electrical parameters

11 × AC connector1 × F connector

Input voltage: AC up to 230 VLine frequency: 50/60 Hz (EU/US)

Operating temperature : 0 °C to 50 °C (32 °F to 122 °F)

Environmental parameters

Product code CXZ-CXP-PH12

Product features and design may vary by version and region.

Package Contents

• Corinex 11+1 Phase Coupler × 1

• Power cord with 2 terminal clamps × 11

power outlet on coupler

coax connector

L1L2L3N

11+1 coupler