    sw-oc-insph#sw-oc-insph#sho running-configBuilding configuration...

    Current configuration : 14700 bytes!version 12.2

    no service padservice timestamps debug datetime msec localtimeservice timestamps log datetime localtimeservice password-encryption!hostname sw-oc-insph!boot-start-markerboot-end-marker!logging buffered informationalenable secret 5 $1$I7OV$usaHrlz916eroTjjYuCtM0

    !username root privilege 15 secret 5 $1$gagM$Br3Tn4hRTuHwfaVkXBwhn.!!aaa new-model!!aaa authentication login default local group tacacs+aaa authentication enable default enable group tacacs+aaa authorization exec default local group tacacs+aaa accounting exec default start-stop group tacacs+aaa accounting commands 15 default start-stop group tacacs+!

    !!aaa session-id commonclock timezone GMT-6 -6clock summer-time GMT recurring 1 Sun Apr 2:00 last Sun Oct 2:00system mtu routing 1500authentication mac-move permitip routingip domain-name ife.org.mx!!!

    !!!!!archivepath ftp://10.0.1.4/archives_ftp/SW_OC_INS/$h/$twrite-memorytime-period 10080!spanning-tree mode pvstspanning-tree extend system-idspanning-tree vlan 11-13,100 priority 24576

    spanning-tree vlan 14-15,20 priority 28672!vlan internal allocation policy ascending

  • 8/6/2019 config R1

    2/11

    !ip ftp username backupsip ftp password 7 08007F19511C174640!!!interface FastEthernet0/1

    description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/2description "IP Phone -- usuario"switchport mode accessswitchport nonegotiate

    power inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/3description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable

    !interface FastEthernet0/4description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/5description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/6description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enable

    spanning-tree portfastspanning-tree bpduguard enable!

  • 8/6/2019 config R1

    3/11

    interface FastEthernet0/7description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfast

    spanning-tree bpduguard enable!interface FastEthernet0/8description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/9

    description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/10description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline never

    no cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/11description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/12description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/13description "IP Phone -- usuario"switchport mode access

    switchport nonegotiatepower inline neverno cdp enable

  • 8/6/2019 config R1

    4/11

    spanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/14description "IP Phone -- usuario"switchport mode accessswitchport nonegotiate

    power inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/15description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfast

    spanning-tree bpduguard enable!interface FastEthernet0/16description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/17description "IP Phone -- usuario"

    switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/18description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/19description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!

    interface FastEthernet0/20description "IP Phone -- usuario"switchport mode access

  • 8/6/2019 config R1

    5/11

    switchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/21

    description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/22description "IP Phone -- usuario"switchport mode accessswitchport nonegotiate

    power inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/23description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable

    !interface FastEthernet0/24description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/25description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/26description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enable

    spanning-tree portfastspanning-tree bpduguard enable!

  • 8/6/2019 config R1

    6/11

    interface FastEthernet0/27description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfast

    spanning-tree bpduguard enable!interface FastEthernet0/28description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/29

    description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/30description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline never

    no cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/31description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/32description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/33description "IP Phone -- usuario"switchport mode access

    switchport nonegotiatepower inline neverno cdp enable

  • 8/6/2019 config R1

    7/11

    spanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/34description "IP Phone -- usuario"switchport mode accessswitchport nonegotiate

    power inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/35description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfast

    spanning-tree bpduguard enable!interface FastEthernet0/36description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/37description "IP Phone -- usuario"

    switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/38description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/39description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!

    interface FastEthernet0/40description "IP Phone -- usuario"switchport mode access

  • 8/6/2019 config R1

    8/11

    switchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/41

    description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/42description "IP Phone -- usuario"switchport mode accessswitchport nonegotiate

    power inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/43description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable

    !interface FastEthernet0/44description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/45description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface FastEthernet0/46description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enable

    spanning-tree portfastspanning-tree bpduguard enable!

  • 8/6/2019 config R1

    9/11

    interface FastEthernet0/47description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfast

    spanning-tree bpduguard enable!interface FastEthernet0/48description "IP Phone -- usuario"switchport mode accessswitchport nonegotiatepower inline neverno cdp enablespanning-tree portfastspanning-tree bpduguard enable!interface GigabitEthernet0/1

    !interface GigabitEthernet0/2!interface GigabitEthernet0/3!interface GigabitEthernet0/4!interface Vlan1description CoordCAGip address 192.168.1.1 255.255.255.0!interface Vlan11description DirDCV

    ip address 172.17.11.253 255.255.255.0ip helper-address 10.100.0.1no ip redirectsip pim sparse-modestandby 1 ip 172.17.11.254standby 1 priority 200standby 1 preemptstandby 1 authentication md5 key-string 7 08131F4A2D4A171117!interface Vlan12description CoordCPTip address 172.17.12.253 255.255.255.0ip helper-address 10.100.0.1no ip redirectsip pim sparse-modestandby 1 ip 172.17.12.254standby 1 priority 200standby 1 preemptstandby 1 authentication md5 key-string 7 08131F4A2D4A171117!interface Vlan13description CoordCAGip address 172.17.13.253 255.255.255.0ip helper-address 10.100.0.1no ip redirects

    ip pim sparse-modestandby 1 ip 172.17.13.254standby 1 priority 200

  • 8/6/2019 config R1

    10/11

    standby 1 preemptstandby 1 authentication md5 key-string 7 073D72486A5A0B0312!interface Vlan14description CoordCOCip address 172.17.14.253 255.255.255.0ip helper-address 10.100.0.1

    no ip redirectsip pim sparse-modestandby 1 ip 172.17.14.254!interface Vlan15description DirEjecutivaip address 172.17.15.253 255.255.255.0ip helper-address 10.100.0.1no ip redirectsip pim sparse-modestandby 1 ip 172.17.15.254!

    interface Vlan20description AccessWIFIip address 172.17.20.253 255.255.255.0ip helper-address 10.100.0.1no ip redirectsip pim sparse-modestandby 1 ip 172.17.20.254!interface Vlan100description AdmonSwitchip address 172.17.100.249 255.255.255.0!!

    router eigrp 8140network 172.17.11.0 0.0.0.255network 172.17.12.0 0.0.0.255network 172.17.13.0 0.0.0.255network 172.17.14.0 0.0.0.255network 172.17.15.0 0.0.0.255network 172.17.20.0 0.0.0.255network 172.17.100.0 0.0.0.255!ip default-gateway 172.17.100.254ip classlessno ip http serverno ip http secure-server!!ip sla enable reaction-alertslogging facility local3logging 10.0.1.4logging 10.100.0.9access-list 40 permit 10.0.1.4access-list 40 permit 10.0.1.90access-list 40 permit 10.100.0.9access-list 41 permit 10.0.1.4access-list 41 permit 10.100.0.9access-list 41 permit 10.100.0.1

    !snmp-server community redife RO 40tacacs-server host 10.100.0.232

  • 8/6/2019 config R1

    11/11

    tacacs-server host 10.100.0.231tacacs-server directed-requesttacacs-server key 7 141A0B005F1D2B38752E60!banner motd ^CCC--------------------------------------------------------------------------------

    ***** ADVERTENCIA *****

    IIIIIIIIIIII FFFFFFFFFFFF EEEEEEEEEEEEIIIIIIIIIIII FFFFFFFFFFFF EEEEEEEEEEEE

    IIII FFFF EEEEIIII FFFFFFF EEEEEEEIIII FFFFFFF EEEEEEEIIII FFFF EEEE

    IIIIIIIIIIII FFFF EEEEEEEEEEEEIIIIIIIIIIII FFFF EEEEEEEEEEEE

    El acceso a este sistema esta reservado a personal autorizado. Todas lasactividades que se realizen durante la sesion seran registradas y monitoreadas.Los intentos de conexion no autorizados seran motivo de investigacion yremitidos a las autoridades competentes.

    --------------------------------------------------------------------------------^C!line con 0exec-timeout 15 0privilege level 0password 7 104A5A0B0344logging synchronoustransport preferred noneline vty 0 4exec-timeout 15 0password 7 08251F5C0F4Atransport input ssh

    line vty 5 15access-class 41 inexec-timeout 15 0password 7 03000819005Ctransport input ssh!ntp clock-period 36029405ntp server 10.0.1.3ntp server 10.100.84.3end

    sw-oc-insph#