ALAIN VIVIER INSTN ACLAY ), GELD REVA A AGUE...RESULTATS MCNP BY COURTESY OF RODOLPHE ANTONI (CEA/C...

157
1 PRESENTATION DES UTILITAIRES DE CALCULS DE LOUVRAGE « CALCUL DE DOSES GENEREES PAR LES RAYONNEMENTS IONISANTS » ( EDP SCIENCES 2012) ALAIN VIVIER (INSTN/SACLAY), GERALD LOPEZ (AREVA NC/ LA HAGUE)

Transcript of ALAIN VIVIER INSTN ACLAY ), GELD REVA A AGUE...RESULTATS MCNP BY COURTESY OF RODOLPHE ANTONI (CEA/C...

  • 1

    PRESENTATION DES UTILITAIRES DE CALCULS DE L’OUVRAGE

    « CALCUL DE DOSES GENEREES PAR LES RAYONNEMENTS IONISANTS »

    ( EDP SCIENCES 2012)

    ALAIN VIVIER (INSTN/SACLAY), GERALD LOPEZ (AREVA NC/ LA HAGUE)

  • 2

    6 CHAPITRES DANS UNE PROGRESSION PEDAGOGIQUE

  • 3

    6 CHAPITRES DANS UNE PROGRESSION PEDAGOGIQUE

    1. CONCEPT DE DOSE ABSORBEE ET CONSIDERATIONS PHYSIQUES GENERALES

    2. INTERACTION PARTICULES CHARGEES-MATIERE ET DOSE ASSOCIEE

    3. INTERACTION PHOTONS-MATIERE ET DOSE ASSOCIEE

    4. INTERACTION NEUTRONS-MATIERE ET DOSE ASSOCIEE

    ( ) ( )Φ,E=M MD d Φ×

    SD Φ

    ρ=

    en.γD( x ) E ( x )

    µ Φρ

    trD EΣ Φρ

  • 4

    6 CHAPITRES DANS UNE PROGRESSION PEDAGOGIQUE

    1. CONCEPT DE DOSE ABSORBEE ET CONSIDERATIONS PHYSIQUES GENERALES

    2. INTERACTION PARTICULES CHARGEES-MATIERE ET DOSE ASSOCIEE

    3. INTERACTION PHOTONS-MATIERE ET DOSE ASSOCIEE

    4. INTERACTION NEUTRONS-MATIERE ET DOSE ASSOCIEE

    5. EFFETS BIOLOGIQUES, GRANDEURS DE PROTECTION ET GRANDEURS OPERATIONNELLES

    ( ) ( )Φ,E=M MD d Φ×

    SD Φ

    ρ=

    en.γD( x ) E ( x )

    µ Φρ

    trD EΣ Φρ

    ,T R T RT R

    E w w D =

    ∑ ∑

  • 5

    6 CHAPITRES DANS UNE PROGRESSION PEDAGOGIQUE

    1. CONCEPT DE DOSE ABSORBEE ET CONSIDERATIONS PHYSIQUES GENERALES

    2. INTERACTION PARTICULES CHARGEES-MATIERE ET DOSE ASSOCIEE

    3. INTERACTION PHOTONS-MATIERE ET DOSE ASSOCIEE

    4. INTERACTION NEUTRONS-MATIERE ET DOSE ASSOCIEE

    5. EFFETS BIOLOGIQUES, GRANDEURS DE PROTECTION ET GRANDEURS OPERATIONNELLES

    6. RELATION DOSE ACTIVITE

    ( ) ( )Φ,E=M MD d Φ×

    SD Φ

    ρ=

    en.γD( x ) E ( x )

    µ Φρ

    trD EΣ Φρ

    ,T R T RT R

    E w w D =

    ∑ ∑

    γenair γ 2

    air

    IµK E

    ρ 4π d

    =

    &A

  • 6

    8 UTILITAIRES DE CALCUL ASSOCIES

  • 7

    8 UTILITAIRES DE CALCUL ASSOCIES

    1. IRM PARTICULES CHARGEES

    2. IRM PHOTONS

    3. COEFFICIENT FLUENCE –EQUIVALENT DE DOSE CIPR 74

    4. SERIOUS GAME 1 D

  • 8

    8 UTILITAIRES DE CALCUL ASSOCIES

    1. IRM PARTICULES CHARGEES

    2. IRM PHOTONS

    3. COEFFICIENT FLUENCE –EQUIVALENT DE DOSE CIPR 74

    4. SERIOUS GAME 1 D

    « PACK DOSIMEX » (RELATION DOSE –ACTIVITE)

    5. DOSIMEX-I : CONTAMINATION INTERNE ET TRANSFERT ATMOSPHERIQUE (DETERMINISTE)

    6. DOSIMEX –B : DOSE EMETTEURS BETA (MONTE-CARLO)

    7. DOSIMEX –N : DOSE NEUTRONS TYPE AM-BE +PROTECTION BIOLOGIQUE (MONTE-CARLO)

    8. DOSIMEX –G : DOSE EMETTEURS GAMMA ET GENERATEURS X (DETERMINISTE)

  • 9

    8 UTILITAIRES DE CALCUL ASSOCIES

    1. IRM PARTICULES CHARGEES

    2. IRM PHOTONS

    3. COEFFICIENT FLUENCE –EQUIVALENT DE DOSE CIPR 74

    4. SERIOUS GAME 1 D

    « PACK DOSIMEX » (RELATION DOSE –ACTIVITE)

    5. DOSIMEX-I : CONTAMINATION INTERNE ET TRANSFERT ATMOSPHERIQUE (DETERMINISTE)

    6. DOSIMEX –B : DOSE EMETTEURS BETA (MONTE-CARLO)

    7. DOSIMEX –N : DOSE NEUTRONS TYPE AM-BE +PROTECTION BIOLOGIQUE (MONTE-CARLO)

    8. DOSIMEX –G : DOSE EMETTEURS GAMMA ET GENERATEURS X (DETERMINISTE)

  • 10

    8 UTILITAIRES DE CALCUL ASSOCIES

    1. IRM PARTICULES CHARGEES

    2. IRM PHOTONS

    3. COEFFICIENT FLUENCE –EQUIVALENT DE DOSE CIPR 74

    4. SERIOUS GAME 1 D

    « PACK DOSIMEX » (RELATION DOSE –ACTIVITE)

    5. DOSIMEX-I : CONTAMINATION INTERNE ET TRANSFERT ATMOSPHERIQUE (DETERMINISTE)

    6. DOSIMEX –B : DOSE EMETTEURS BETA (MONTE-CARLO)

    7. DOSIMEX –N : DOSE NEUTRONS TYPE AM-BE +PROTECTION BIOLOGIQUE (MONTE-CARLO)

    8. DOSIMEX –G : DOSE EMETTEURS GAMMA ET GENERATEURS X (DETERMINISTE)

  • 11

    8 UTILITAIRES DE CALCUL ASSOCIES

    1. IRM PARTICULES CHARGEES

    2. IRM PHOTONS

    3. COEFFICIENT FLUENCE –EQUIVALENT DE DOSE CIPR 74

    4. SERIOUS GAME 1 D

    « PACK DOSIMEX » (RELATION DOSE –ACTIVITE)

    5. DOSIMEX-I : CONTAMINATION INTERNE ET TRANSFERT ATMOSPHERIQUE (DETERMINISTE)

    6. DOSIMEX –B : DOSE EMETTEURS BETA (MONTE-CARLO)

    7. DOSIMEX –N : DOSE NEUTRONS TYPE AM-BE +PROTECTION BIOLOGIQUE (MONTE-CARLO)

    8. DOSIMEX –G : DOSE EMETTEURS GAMMA ET GENERATEURS X (DETERMINISTE)

  • 12

    8 UTILITAIRES DE CALCUL ASSOCIES

    1. IRM PARTICULES CHARGEES

    2. IRM PHOTONS

    3. COEFFICIENT FLUENCE –EQUIVALENT DE DOSE CIPR 74

    4. SERIOUS GAME 1 D

    « PACK DOSIMEX » (RELATION DOSE –ACTIVITE)

    5. DOSIMEX-I : CONTAMINATION INTERNE ET TRANSFERT ATMOSPHERIQUE (DETERMINISTE)

    6. DOSIMEX –B : DOSE EMETTEURS BETA (MONTE-CARLO)

    7. DOSIMEX –N : DOSE NEUTRONS TYPE AM-BE +PROTECTION BIOLOGIQUE (MONTE-CARLO)

    8. DOSIMEX –G : DOSE EMETTEURS GAMMA ET GENERATEURS X (DETERMINISTE)

  • 13

    APPLICATIONS « IRM PARTICULES CHARGEES »

    EXEMPLES AVEC PARTICULE ALPHA ET ELECTRON DE 5 MEV + SPECTRE BETA

  • 14

  • 15

    PARTICULE αααα

  • 16

  • 17

    EAU

  • 18

  • 19

  • 20

  • 21

  • 22

    TISSUS BIO.

  • 23

  • 24

  • 25

  • 26

  • 27

    ELECTRON

  • 28

    PARCOURS SIGNIFICATIVEMENT PLUS ELEVEE

  • 29

    PARCOURS SIGNIFICATIVEMENT PLUS ELEVEE

    EQUIVALENT DE DOSE PLUS FAIBLE

  • 30

    PARCOURS SIGNIFICATIVEMENT PLUS ELEVEE

    EQUIVALENT DE DOSE PLUS FAIBLE

    POUVOIR D’ARRET CONSTANT SUR LE PARCOURS

  • 31

    PARCOURS SIGNIFICATIVEMENT PLUS ELEVEE

    EQUIVALENT DE DOSE PLUS FAIBLE

    POUVOIR D’ARRET CONSTANT SUR LE PARCOURS

    LIE AU CARACTERE ULTRARELATIVISTE DE L’ELECTRON

    (>500 KEV)

  • 32

    EMETTEUR BETA

  • 33

    CARACTERISTIQUE TRANSITION

    BETA

  • 34

    SPECTRE D’EMISSION

  • 35

    SCHEMA D’IRRADIATION

    SPECTRE CONDENSE DU CS 137

    1GBQ A 30 CM DANS L’AIR

  • 36

  • 37

    SPECTRE DEGRADE PAR 30 CM

    D’AIR

  • 38

    PROFIL DE DOSE DANS 2 MM DE

    PEAU

  • 39

    VALEUR MOYENNE DE DOSE SUR

    2 MM

  • 40

    VALEUR SOUS 70 µM DE

    COUCHE MORTE (H’(0,07))

  • 41

    H’(0,07)=92 mSV.H-1

  • 42

    COMPARAISON :

    GUIDE PRATIQUE DELACROIX : 100 mSV.H-1

    H’(0,07)=92 mSV.H-1

  • 43

    COMPARAISON :

    GUIDE PRATIQUE DELACROIX : 100 mSV.H-1

    DOSIMEX-B : 104 mSV.H-1

    H’(0,07)=92 mSV.H-1

  • 44

    H’(0,07)≈ 5 HMOY

    HMOY=20 mSV.H-1

  • 45

  • 46

  • 47

    VISUALISATION TRAJECTOIRE DE PHOTONS DE 2 MEV

    DANS L’EAU PUIS DANS LE PLOMB

    (EXTRAIT UTILITAIRE « IRM PHOTON »)

  • 48

    CAPACITE DE PENETRATION ELEVEE

  • 49

    EFFETS DE DIFFUSION

    PREDOMINANT

  • 50

    EFFETS DE DIFFUSION

    PREDOMINANT

  • 51

    POSSIBILITE DE RETRODIFFUSION

    NON NEGLIGEABLE

  • 52

    ABSORPTION TOTALE PEU

    PROBABLE

  • 53

    PHOTONS DE 2 MEV DANS LE PLOMB

  • 54

    CAPACITE DE PENETRATION PEU

    ELEVEE

  • 55

    DIFFUSION LIMITEE

  • 56

    DIFFUSION LIMITEE

  • 57

    EXEMPLE DE TRAJECTOIRE

    EXCEPTIONNELLEMENT PENETRANTE

  • 58

    TRAJECTOIRE PLUS FREQUENTE

  • 59

    OU L’ON COMPREND QUE LE PLOMB EST UN BON ECRAN DE

    PROTECTION VIS-A-VIS DES PHOTONS

    ET PAS L’EAU !

  • 60

    TRAJECTOIRES DE NEUTRONS DE 5 MEV EMIS

    DU CENTRE D’UNE SPHERE D’EAU DE RAYON 25 CM

    (EXTRAIT DE DOSIMEX-N)

  • 61

    THERMALISATION ET FUITE

  • 62

    THERMALISATION ET CAPTURE

  • 63

    THERMALISATION ET CAPTURE

  • 64

    THERMALISATION EFFICACE (≈ 16CHOCS) PUIS FUITE OU CAPTURE

    TRANSMISSION EN FLUENCE : 19 %

    TRANSMISSION EN DOSE : 12 %

    Spectre neutrons émergeants

    20,1%

    5,2%3,3% 2,4% 1,8%

    6,0% 6,4%

    54,8%

    0,0%

    1 2 3 4 5 6 7 8 9groupes

    SPECTRE DE RALENTISSEMENT

  • 65

    TRAJECTOIRES DE NEUTRONS DE 5 MEV EMIS

    DU CENTRE D’UNE SPHERE DE PLOMB DE 25 CM DE RAYON

  • 66

    FUITE DU NEUTRON

    AVEC UNE ENERGIE DE 4,2 MEV

  • 67

    FUITE DU NEUTRON

    AVEC UNE ENERGIE DE 4,1 MEV

  • 68

    FUITE DU NEUTRON

    AVEC UNE ENERGIE DE 4,3 MEV

  • 69

    ABSENCE DE THERMALISATION ET DE CAPTURE

    • TRANSMISSION EN FLUENCE :100 %

    • TRANSMISSION EN DOSE : 102 %

    OU L’ON COMPREND QUE LE PLOMB EST N’EST PAS UN BON ECRAN DE PROTECTION VIS-A-VIS DES NEUTRONS

    CONTRAIREMENT A L’EAU !!

    Spectre neutrons émergeants

    0,0% 0,0% 0,0% 0,0% 0,0% 0,1% 0,3%

    99,6%

    0,0%

    1 2 3 4 5 6 7 8 9groupes

  • 70

    Dose Neutron 5 MeV dans l'eau vs Rayon

    1,0E-08

    1,0E-07

    1,0E-06

    1,0E-05

    1,0E-04

    1,0E-03

    1,0E-02

    1,0E-01

    1,0E+00

    1,0E+01

    0 c

    m

    2.5

    5 c

    m

    7.5

    10

    cm

    20

    cm

    30

    cm

    40

    cm

    50

    cm

    75

    cm

    10

    0 c

    m

    15

    0 c

    m

    20

    0 c

    m

    MCNP n+g

    DOSIMEX n+gamma

    DOSIMEX neutron seul

    RESULTATS MCNP BY COURTESY OF RODOLPHE ANTONI (CEA/CAD) ET LAURENT BOURGOIS (CEA/DAM DIF)

    DOSIMEX-N VS MCNP

    A PARTIR DE 75 CM D’EAU, CE SONT LES GAMMA DE

    CAPTURE QUI PREDOMINENT

  • 71

    EXEMPLE PEDAGOGIQUE AVEC DOSIMEX-G

  • 72

    EXEMPLE PEDAGOGIQUE AVEC DOSIMEX-G

    MODELISATION SIMPLIFIEE D’UN CONTENEUR DE DECHETS VITRIFIES

  • 73

    EXEMPLE PEDAGOGIQUE AVEC DOSIMEX-G

    MODELISATION SIMPLIFIEE D’UN CONTENEUR DE DECHETS VITRIFIES

  • 74

    EXEMPLE PEDAGOGIQUE AVEC DOSIMEX-G

    MODELISATION SIMPLIFIEE D’UN CONTENEUR DE DECHETS VITRIFIES

    Si 2,3 g /cm3

    Cs 137 :2E16 Bq

    Cs 134 :5E15 Bq

    Rh 106 :2E15 Bq

    Φ= 40cm

    H=130cm

    Fe 1cm

    d=100cm

  • 75

  • 76

  • 77

    CHOIX RADIONUCLEIDE

  • 78

    2E16 BQ DE CESIUM 137 (6,25 KG)

  • 79

    5E15 BQ DE CESIUM 134 (0,10 KG)

  • 80

    2E15 BQ DE RHODIUM 106 (16 G)

  • 81

    CHOIX MATRICE SOURCE

  • 82

    ECRAN FER POUR MODELISER LE

    CONTAINER EN ACIER (1 CM)

  • 83

    TEMPS D’INTEGRATION : QQS MN

  • 84

  • 85

    MERCURAD :

    205 Gy/H

    MERCURAD :

    624 Gy/H

    By courtesy of Jean-Lionel TROLET of the Ecole des Applications Militaires de l’Energie Atomique

  • 86

    MERCURAD :

    205 Gy/H

    MERCURAD :

    624 Gy/H

    By courtesy of Jean-Lionel TROLET of the Ecole des Applications Militaires de l’Energie Atomique

    Pour info

    Microshield :

    454 Gy/H

  • 87

    FEUILLE DE SYNTHESE DES RESULTATS

  • 88

    MISE EN PLACE D’UN ECRAN DE PROTECTION :

    15 CM DE PLOMB

  • 89

  • 90

  • 91

    MERCURAD :

    853 µGy/H

    MERCURAD :

    1,05 mGy/H

  • 92

    MERCURAD :

    853 µGy/H

    MERCURAD :

    1,05 mGy/H

    Pour info

    Microshield :

    0,63 mGy/H

  • 93

    UNE SPECIFICITE DE DOSIMEX –G :

  • 94

    UNE SPECIFICITE DE DOSIMEX –G :

    LE MAILLAGE EN PUISSANCE AUTO-ADAPTATIF

  • 95

    UNE SPECIFICITE DE DOSIMEX –G :

    LE MAILLAGE EN PUISSANCE AUTO-ADAPTATIF

    A LA SUITE DE LA REMARQUE L’UN DE NOS PREMIERS UTILISATEURS :

  • 96

    UNE SPECIFICITE DE DOSIMEX –G :

    LE MAILLAGE EN PUISSANCE AUTO-ADAPTATIF

    A LA SUITE DE LA REMARQUE L’UN DE NOS PREMIERS UTILISATEURS :

    « LORSQUE JE CALCULE A DES DISTANCES PLUS FAIBLES, LA DOSE DIMINUE »

  • 97

    UNE SPECIFICITE DE DOSIMEX –G :

    LE MAILLAGE EN PUISSANCE AUTO-ADAPTATIF

    A LA SUITE DE LA REMARQUE L’UN DE NOS PREMIERS UTILISATEURS :

    « LORSQUE JE CALCULE A DES DISTANCES PLUS FAIBLES, LA DOSE DIMINUE »

    PALSAMBLEU !

  • 98

    UNE SPECIFICITE DE DOSIMEX –G :

    LE MAILLAGE EN PUISSANCE AUTO-ADAPTATIF

    A LA SUITE DE LA REMARQUE L’UN DE NOS PREMIERS UTILISATEURS :

    « LORSQUE JE CALCULE A DES DISTANCES PLUS FAIBLES, LA DOSE DIMINUE »

    PALSAMBLEU !

    IL CODAIT UN SILO DE 9 M DE HAUT ET DE 4 M DE DIAMETRE !!

  • 99

    UNE SPECIFICITE DE DOSIMEX –G :

    LE MAILLAGE EN PUISSANCE AUTO-ADAPTATIF

    A LA SUITE DE LA REMARQUE L’UN DE NOS PREMIERS UTILISATEURS :

    « LORSQUE JE CALCULE A DES DISTANCES PLUS FAIBLES, LA DOSE DIMINUE »

    PALSAMBLEU !

    IL CODAIT UN SILO DE 9 M DE HAUT ET DE 4 M DE DIAMETRE !!

    EFFET DE MAILLAGE TROP GROSSIER

  • 100

    SOLUTION :

  • 101

    SOLUTION :

    POUR EVITER D’AUGMENTER LE NOMBRE DE MAILLE (15)

    (TEMPS DE CALCULS REDHIBITOIRES)

  • 102

    SOLUTION :

    POUR EVITER D’AUGMENTER LE NOMBRE DE MAILLE (15)

    (TEMPS DE CALCULS REDHIBITOIRES)

    MAILLER FIN EN REGARD DU DETECTEUR ET PLUS GROSSIEREMENT

    EN PROFONDEUR (MAILLAGE EN PUISSANCE)

  • 103

    SOLUTION :

    POUR EVITER D’AUGMENTER LE NOMBRE DE MAILLE (15)

    (TEMPS DE CALCULS REDHIBITOIRES)

    MAILLER FIN EN REGARD DU DETECTEUR ET PLUS GROSSIEREMENT

    EN PROFONDEUR (MAILLAGE EN PUISSANCE)

    +

    2) DIMENSIONNER LA PREMIERE MAILLE EN FONCTIONS DES LIBRES PARCOURS

    MOYENS DES PHOTONS

  • 104

  • 105

  • 106

    EXEMPLE DE MAILLAGE ADAPTE POUR UNE EPAISSEUR DE 100 CM DE PLOMB

    59 KEV : PREMIERE MAILLE : 70 µM

    59 KEV : DERNIERE MAILLE : 46 CM

  • 107

    EXEMPLE DE MAILLAGE ADAPTE POUR UNE EPAISSEUR DE 100 CM DE PLOMB

    1250 KEV : PREMIERE MAILLE : 6 MM

    1250 KEV : DERNIERE MAILLE : 23

    CM

  • 108

    VOLUME SOURCE PB CONTAMINE DE FAÇON HOMOGENE EN AM 241

  • 109

    VOLUME SOURCE PB CONTAMINE DE FAÇON HOMOGENE EN AM 241

  • 110

    VOLUME SOURCE PB CONTAMINE DE FAÇON HOMOGENE EN AM 241

    LE DEBIT DE DOSE NE PEUT QU’AUGMENTER LORSQUE LA HAUTEUR D U CYLINDRE AUGMENTE

  • 111

    VOLUME SOURCE PB CONTAMINE DE FAÇON HOMOGENE EN AM 241

    LE DEBIT DE DOSE NE PEUT QU’AUGMENTER LORSQUE LA HAUTEUR D U CYLINDRE AUGMENTE

  • 112

    Variation dose vs hauteur du cylindre

    0

    500

    1000

    1500

    2000

    2500

    3000

    0,01 0,1 1 10 100H (cm)

    DE

    D (

    nS

    v/h

    )

  • 113

    Variation dose vs hauteur du cylindre

    0

    500

    1000

    1500

    2000

    2500

    3000

    0,01 0,1 1 10 100H (cm)

    DE

    D (

    nS

    v/h

    )

    DOSIMEX-G

  • 114

    Variation dose vs hauteur du cylindre

    0

    500

    1000

    1500

    2000

    2500

    3000

    0,01 0,1 1 10 100H (cm)

    DE

    D (

    nS

    v/h

    )

    DOSIMEX-G

    MICROSHIELD

  • 115

    Variation dose vs hauteur du cylindre

    0

    500

    1000

    1500

    2000

    2500

    3000

    0,01 0,1 1 10 100H (cm)

    DE

    D (

    nS

    v/h

    )DOSIMEX-G

    MICROSHIELD

    MERCURAD uniforme

  • 116

    Variation dose vs hauteur du cylindre

    0

    500

    1000

    1500

    2000

    2500

    3000

    0,01 0,1 1 10 100H (cm)

    DE

    D (

    nS

    v/h

    )DOSIMEX-GMICROSHIELDMERCURAD puissanceMERCURAD uniforme

  • 117

    RAYON : 1000 KM !

  • 118

  • 119

  • 120

    CHOIX SOURCE « GENERATEUR X »

  • 121

    2 OPTIONS DISPONIBLES

  • 122

    OPTION CALCUL DEBIT DE DOSE DANS LE

    FAISCEAU PRIMAIRE

  • 123

  • 124

  • 125

  • 126

  • 127

    CALCUL EN L’ABSENCE DE FILTRATION

  • 128

    DEBIT DE KERMA AIR ELEVE

  • 129

    KERMA GENERE ESSENTIELLEMENT

    PAR LES FAIBLES ENERGIES

  • 130

    MISE EN PLACE D’UNE FILTRATION

    (2 MM D’AL)

  • 131

  • 132

    LE KERMA AIR CHUTE DE 209 mGY/MIN

    A 14 mGY/MIN

  • 133

    SPECTRE SANS FILTRATION

  • 134

    SPECTRE AVEC FILTRATION

    TRES EFFICACE SUR LES FAIBLES ENERGIES

  • 135

  • 136

  • 137

  • 138

    OPTION APPLICATION NORME NF C15-160

  • 139

  • 140

  • 141

  • 142

  • 143

  • 144

  • 145

  • 146

  • 147

  • 148

  • 149

  • 150

  • 151

    RESULTATS STRICTEMENT CONFORME AUX RESULTATS DE LA

    NORME

  • 152

    LES PROCHAINES EVOLUTIONS DE DOSIMEX –G, TOUJOURS EN FONCTION DES DEMANDES UTILISATEURS :

  • 153

    LES PROCHAINES EVOLUTIONS DE DOSIMEX –G, TOUJOURS EN FONCTION DES DEMANDES UTILISATEURS :

    • SOURCE GAMMA : CALCUL DANS UN VOLUME AVEC DES SURFACES CONTAMINEES

  • 154

    LES PROCHAINES EVOLUTIONS DE DOSIMEX –G, TOUJOURS EN FONCTION DES DEMANDES UTILISATEURS :

    • SOURCE GAMMA : CALCUL DANS UN VOLUME AVEC DES SURFACES CONTAMINEES

    • CALCUL ACTIVITE VS DOSE

  • 155

    LES PROCHAINES EVOLUTIONS DE DOSIMEX –G, TOUJOURS EN FONCTION DES DEMANDES UTILISATEURS :

    • SOURCE GAMMA : CALCUL DANS UN VOLUME AVEC DES SURFACES CONTAMINEES

    • CALCUL ACTIVITE VS DOSE

    • GENERATEUR X :CHOIX ANODE + REGLAGE ANGLE

  • 156

    ET DEJA DISPONIBLE EN VERSION D’ESSAI : LE CODE TAGE (TOTAL ABSORPTION GAMMA EFFICIENCY)

    Rendements d'absorption totale vs énergie photon

    0,00E+00

    1,00E-03

    2,00E-03

    3,00E-03

    4,00E-03

    5,00E-03

    6,00E-03

    0 keV 200 keV 400 keV 600 keV 800 keV 1000 keV 1200 keV 1400 keV 1600 keV 1800 keV 2000 keV

    Rendement d'absortion totale calculé

    Valeurs expérimentales

  • 157

    MERCI DE VOTRE ATTENTION