300 90 004 ED8 HAND - Delta Light · Ref: 300 90 004 ED8 2 Installation Instruction mesh network...

7
Last Update ALLU 31/05/2016 Installation Instruction WIRELESS CONTROL DIM8 A A B B A + 1 Ref: 300 90 004 ED8 2 Beschermd tegen vaste voorwerpen die groter zijn dan 12 mm Protégé contre les objets solides de plus de 12 mm Geschützt gegen Festkörper größer als 12 mm Protected against solid objects greater than 12 mm Protegido contra objetos sólidos superiores a 12 mm Protetto contro oggetti solidi più grandi di 12 mm Goederen zijn dubbel geïsoleerd - geen aarding nodig Les produits ont une isolation double et ne peuvent pas être mis à la terre Güter sind doppelt isoliert und müssen nicht geerdet werden Goods have double insulation and must not be grounded Los productos tienen u aislamiento doble y no se pueden conectar a tierra I proditti possiedono un doppio isolamento e non devono essere collegati a terra 36,3 14 40,4 85-240V / 50-60Hz Max. 0.65A +/-7mm L N L' N' 0,75-1,5mm² L N 1 L N 85-240 VAC 19,7 19,7 36,3 39,4 40,4 18,15 18,15 12,7 Mounting hole diameter: 3,5 mm 14,0 L N N L N N L N N Wire info: Solid and stranded: 0,5-1,5 mm² / 16-20AWG

Transcript of 300 90 004 ED8 HAND - Delta Light · Ref: 300 90 004 ED8 2 Installation Instruction mesh network...

Last Update ALLU 31/05/2016

Installation Instruction

WIRELESS CONTROL DIM8

A

A

B

B

A+

1Ref: 300 90 004 ED8

2

Beschermd tegen vaste voorwerpen die groter zijn dan 12 mm

Protégé contre les objets solides de plus de 12 mm

Geschützt gegen Festkörper größer als 12 mm

Protected against solid objects greater than 12 mm

Protegido contra objetos sólidos superiores a 12 mm

Protetto contro oggetti solidi più grandi di 12 mm

Goederen zijn dubbel geïsoleerd - geen aarding nodig

Les produits ont une isolation double et ne peuvent pas être mis à la terre

Güter sind doppelt isoliert und müssen nicht geerdet werden

Goods have double insulation and must not be grounded

Los productos tienen u aislamiento doble y no se pueden conectar a tierra

I proditti possiedono un doppio isolamento e non devono essere collegati a terra

36,3

14

40,4

85-240V / 50-60Hz

Max. 0.65A

+/-7mm

L

N

L'

N'

0,75-1,5mm²

L

N

1

L

N

85-240 VAC

19,7 19,7

36,3

39,4

40,4

18,15

18,1512,7

Mounting hole diameter:

3,5 mm

14,0

LN

N

L N

N

L N

N

Wire info:

Solid and stranded: 0,5-1,5 mm² / 16-20AWG

3 TECHNICAL DATA

2Ref: 300 90 004 ED8

Installation Instruction

mesh network technologyDevice acts also as a repeater. Longer ranges can

be achieved by using multiple Casambi units.

50 m 1)Up to

40 m 1)

Range is highly dependant on the surrounding and obstacles, such as walls and building materials.1)

INPUT

Voltage range: 85-240VFrequency: 50-60HzMax.mains current: 0,65A

OUTPUT

Dimming method: Trailing-edge phase controlMax. output power:Incandescent and high voltage halogen bulbs 150W @ 230VAC 70W @ 110VACHigh voltage ACLED modules: 150W @ 230VAC 70W @ 110VACDimmable LED and CFL bulbs: 50W @ 230VAC 25W @ 110VACDimmable Electronictransformers: 50W @ 230VAC 25W @ 110VACMax. output current: 0,65AMin. load requirement: 1WMax. current pulse: 4A

RADIO TRANSCEIVER

Operating frequencies: 2,4...2,483 GhzMaximum output power: +4 dBm

OPERATING CONDITIONS

Ambient temperature, TA: -20...+45°CMax. case temperature, TC : +65°CStorage temperature: -25...+75°CMax. relative humidity: 0...80%, non cond

CONNECTORS

Wire range, solid & stranded: 0,5-1,5mm² 16-20AWGWire strip length: 6-8mm

MECHANICAL DATA

Dimensions: 40,4 x 36,3 x 14 mmWeigth: 15gDegree of protection: IP20 (Indoor)

Never connect inductive loads, such as iron core transformers.

This could cause permanent damage to the dimmer.

Do not mix di�erent types of loads.

1) Dimming quality depends solely on the load electronics.2) Do not connect more than two electronic transformers to one CBU-TED.3) Some LED modules may �icker at low dimming levels.

LOAD SUITABLITY

TYPE OF LOAD MAX. LOAD Incandescent and High voltage halogens (R) 150WHigh quality dimmable LED bulbs (C)1) 50WHigh quality dimmable CFL bulbs (C)1) 50WTrailing edge dimmable LED drivers (C)1) 2) 50WLow voltage halogens withelectronic transformers(C)1) 2) 50WHigh voltage AC LED modules(R)3) 150WLuminescent lamps, non-dimmable LED and CFL bulbs (C) NOT ALLOWEDWire wound transformers, electric motors and other inductive loads (l) NOT ALLOWED

3